- 34 -
www.NewLeader.com
(800) 363-1771
307074-AA-I
L4000G4
Insert Installation Instructions
Recommended sequence of installation is:
1�
Spreader preparation�
2�
Insert preparation�
3�
Mounting of insert�
4�
Connecting hydraulic hoses�
5�
Installation of hillside divider and conveyor cover�
6�
Checking installation�
7�
Checking for leaks and proper functioning�
Hydraulic Requirements
Refer to”Hydraulic Requirements” on page 25
for hydraulic pump part numbers and specifications
required for insert installation�
Spreader Preparation
Use only lifting devices that meet or exceed OSHA standard 1910�184� Never exceed work
load limits or lift equipment over people� Empty spreader before lifting� Loads may shift
or fall if improperly supported, causing injury� Failure to comply with this requirement could
result in death or serious injury�
Figure 1
Remove the Inverted “V” and Hillside Divider from
the spreader, if so equipped, and set hardware
aside�
Remove Feedgate Jack Handle and set aside�
Support endgate by attaching a hoist to the lift
hooks� Remove hardware from both sides of the
endgate and carefully remove from the spreader as
shown in Figure 1�
NOTE: Always use a sling, spreader bar, or
lifting bar that attaches to the lifting points with
a minimum of 60 degrees from horizontal� It is
preferable to use a straight style lifting bar that
keeps the attaching chains in a near vertical
orientation�
NOTE: Always inspect unit lift hooks for signs of
wear, cracking, corrosion, gouges, alterations, or
distortion before use�
The
M
ult
A
pplier
is available in two different styles; Style I and Style II� The Style II
M
ult
A
pplier
provides higher output capabilities� Refer to next page to determine your style
of
M
ult
A
pplier
insert�