- 22 -
7-5. Maker Mode
All the items set in Maker mode (e.g. alarm set value) are password-protected.
7-5-1. Maker Mode Activation
There are two methods to enter Maker mode.
1. Turn off the detector. Then simultaneously press and hold the
▲
and
▼
and POWER buttons
for three seconds (two beeps) to activate Maker mode.
2. Press and hold the maintenance button while in normal operation mode.
The software version is displayed, followed by all the LCD segments displayed, and finally
“775”
starts flashing. Now Maker mode is active.
▪
Incorrect settings in Maker mode may change the detector
’s specifications. Never
operate in a way other than as described in this instruction manual.
▪
Only a selected administrator should make changes in Maker mode.
▪
Gas detection is not possible while in Maker mode. To exit and return to normal
operation, power cycle the unit before use.
WARNING
Software version
All LCD segments
turn on
“775” flashes.
Maker Mode is active.
Maintenance
button
Main power switch
Only enter 775 to enter Maker mode.
CAUTION