12
PRE-FAB FIREPLACE INSERT
INSTALLATION
Figure 7
IMPORTANT: READ ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL
THESE UNITS.
1. For clearance see Figure 7.
2. Failure to follow instructions will result in improper burning of unit and voids all
warranties and liability of manufacturer.
NOTE:
Do not allow the combustion and ventilation air to be obstructed. Combustion air
enters at the bottom of this unit.
3. All units must be vented with 4" pipe from top of unit to entire height of existing
chimney.
CAUTION:
Read 1 - 7, page 9 carefully before lighting your unit for the first time.
NOTE: TRIM PANELS CANNOT COVER EXISTING COOLING OR LOUVERED
VENTS ON ANY PRE-FAB FIREPLACE.
NOTE: IF THE BOTTOM OF THE HEATER IS LESS THAN 7" (177mm) FROM
COMBUSTIBLE MATERIALS ON THE FLOOR WHEN INSTALLED, YOU MUST
HAVE A FLOOR PROTECTOR 12" (304mm) FROM THE FRONT OF THE HEATER.
NOTE:
A tube is located at the top of the unit behind brass louvers. This tube is used to check
draft of unit after it has been installed as an insert.
MANTEL AND/ OR SUPPORTS
COMBUSTIBLE PROJECTING
MORE THAN 3/4”