Spate cleaner TANKO-SF
5 Installation
Translation of the original Operating / Installation Instructions 2016/09 Rev.1 27/63
5.2.3
Installing the Device
NOTE
Risk of dirt and foreign objects in the device!
Functional safety and reliability may be compromised.
During installation, make sure and check that there is no dirt or foreign bodies in the device
(e.g. small particles, sealing material).
Installation with Clipon Variant
Wire locking pin as delivered
Picture 5.2-3: Clipon Installation
NOTE
Multiple utilization of the wire locking pin.
The material experiences fatigue and loses its rigidity when the wire locking pin is subjected to multiple
bending. The nozzle carrier may come loose.
The device and the wire locking pin could fall into the container.
The wire locking pin is to be replaced by a new wire locking pin after it has been bent (see
section 7.5.1
NOTE
Non-observance of the dimensions for the media connection (see
Problems with the fastening of the device to the downpipe could be the result.
The distance between the bore hole for the clip in the downpipe and the end of the downpipe may
not exceed a maximum of 8 mm.
The bore hole diameter for the clip in the downpipe is 3.2 mm.
1.
Slide the axle (1) over the downpipe and rotate it until the clip bore holes in the downpipe match the
clip boreholes in the axle (1).
2.
Insert the wire locking pin (5) through the bore holes in the downpipe and axle (1) until it hits the
stopper.
3.
Bend the straight end of the wire locking pin (5) with the assembly/disassembly tool for the locking
pin 2.4 mm by at least 45° (see
Picture 5.2-3: Clipon Installation
4.
Check whether the cage can rotate freely.