8 Faults
8.3
How to Act in Case of an Emergency
If a hazardous situation occurs, or if you need to avert a potential danger, quickly set the device to a
safe state.
The type of EMERGENCY STOP circuit used for the device is to be determined depending on the hazards
and operating conditions and is the sole responsibility of the operating company.
It is for this reason that AWH can offer the operating company, solely as a precautionary measure, a few
points of reference and notes to be observed and to be integrated into the operating company's hazard
assessments.
–
The working steps listed in
section 7.2 Switch-off
must be adhered to for switching off the
device.
–
The EMERGENCY STOP circuit must be designed in such a way that the machine or system operator
can actuate it immediately in the event of an emergency.
–
Switching off with the “EMERGENCY STOP” in case of emergency is designed to disconnect the entire
machine from the supply voltage without delay in order to eradicate the risks caused by electrical
voltage immediately.
–
Shutting down in case of emergency using the “EMERGENCY STOP” is intended to prevent risks
which cause hazardous movements as soon as possible.
–
The EMERGENCY STOP must have priority over all other functions and actuations in all operating modes.
–
Resetting must not cause the plant/machine to start up again.
Source:
–
DIN EN 60204-1 / VDE 0113-1 “Safety of machinery – Electrical equipment of machines –
Part 1: General requirements”
–
DIN EN ISO 13850: “Safety of machinery - Emergency stop - Principles for design”
In Case of Emergency:
Trigger the EMERGENCY STOP function on the higher-level plant / machine.
Actuate the EMERGENCY STOP switch
Interrupt actuating energy supply!
–
Interrupt electricity supply (e.g. electrical actuator)
–
Switch off higher-level main switch
–
Pull out power plug
–
Close the compressed air shut-off valve (e.g. pneumatic actuator)
Interrupt the supply of cleaning agent (actuator energy)
–
Close the shut-off valve