Network Technologies Incorporated ENVIROMUX E-BCN-R Installation Manual Download Page 2

NTI ENVIROMUX SENSOR INSTALLATION 

 

1

 

 

TABLE OF CONTENTS 

 

 

Introduction...................................................................................................................................................................... 2

 

Connect Sensors to E-MINI-LXO /-MICRO-T(rhp).......................................................................................................... 2

 

E-T or TRHM-E7.......................................................................................................................................................... 2

 

Sensor Cable ............................................................................................................................................................... 3

 

E-LD............................................................................................................................................................................. 4

 

Contact Sensors .......................................................................................................................................................... 5

 

Connect Sensors to The E-xD Models............................................................................................................................ 6

 

RJ45 Sensors .............................................................................................................................................................. 6

 

Temperature, Humidity Sensors ............................................................................................................................... 6

 

Contact Sensors ....................................................................................................................................................... 7

 

Digital In Terminals................................................................................................................................................ 7

 

Liquid Detection Sensors.......................................................................................................................................... 9

 

BEACON and SIREN Connections ........................................................................................................................... 10

 

RJ45 Sensor Cable.................................................................................................................................................... 11

 

Liquid Detection False Alert Fix ................................................................................................................................. 11

 

 

 

 

 

 

TABLE OF FIGURES

 

 

 

 

Figure 1- Connect sensors to E-MINI-LXO ........................................................................................................................................ 2

 

Figure 2- Liquid detection sensor....................................................................................................................................................... 4

 

Figure 3- Terminal block for dry-contact sensors ............................................................................................................................... 5

 

Figure 4- Sensors connected by cables with RJ45 connectors.......................................................................................................... 6

 

Figure 5- A portion of the sensor configuration page ......................................................................................................................... 6

 

Figure 8- Contact sensor wired to RJ45 socket ................................................................................................................................. 7

 

Figure 9- “DIGITAL IN” terminal blocks on ENVIROMUX Systems ................................................................................................... 7

 

Figure 10- Basic DIGITAL IN Terminal Connections ......................................................................................................................... 8

 

Figure 11- Secure liquid detection sensor with tape .......................................................................................................................... 9

 

Figure 12- Portion of Water Sensor configuration page ..................................................................................................................... 9

 

Figure 13- Connect visual and audible external indicators............................................................................................................... 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ENVIROMUX E-BCN-R

Page 1: ...Date 5 7 2018 Sensor Installation Manual ENVIROMUX Series E T TRHM E7 Temperature Humidity sensors E LDSx y Liquid Detection Sensor E BCN R Beacon E SRN M Siren E M DCS3 Door Contact Switch E TDS Tam...

Page 2: ...e Alert Fix 11 TABLE OF FIGURES Figure 1 Connect sensors to E MINI LXO 2 Figure 2 Liquid detection sensor 4 Figure 3 Terminal block for dry contact sensors 5 Figure 4 Sensors connected by cables with...

Page 3: ...MICRO T RHP E T or TRHM E7 For measuring temperature and humidity the E MINI LXO and E MICRO T RHP uses the E T E7 temperature only E TRHM E7 combination temperature and humidity sensor For high tempe...

Page 4: ...n a 2 25 F 1 25 C Sensor Cable The CAT5 connection cable between the E MINI LXO E MICRO T RHP and the RJ45 Sensors is terminated with RJ45 connectors and must be wired according to the EIA TIA 568 B i...

Page 5: ...oblems after you have cleaned it with isopropyl alcohol or if you think the rope needs a good scrubbing you can clean it with warm soapy water You will have to remove the rope from its installed locat...

Page 6: ...h E M DCS3 Door Contact Sensor E DCS PS2 Plunger Style Door Contact Sensor To install the dry contact sensor s A Attach the positive lead to a terminal corresponding to a marking on the E MINI LXO and...

Page 7: ...ing temperature and humidity sensors to the ENVIROMUX the web interface will identify the sensor accordingly for the type of sensor it is The status bar and configuration page will enter the maximum a...

Page 8: ...ensors for plug in to the RJ45 Sensor sockets the following socket to sensor wiring must be followed RJ45 Sensor Socket Pinout Pin Pin Name 1 GND 2 SENSE 3 RS485 4 5 VDC 5 TAMPER SWITCH 6 RS485 7 12 V...

Page 9: ...NTI ENVIROMUX SENSOR INSTALLATION 8 Figure 8 Basic DIGITAL IN Terminal Connections...

Page 10: ...sure to only apply tape to the ends exposing as much of the sensor as possible At least 5 8 of the sensor must be exposed for it to function See Figure 2 Figure 9 Secure liquid detection sensor with t...

Page 11: ...tention All devices must be installed using 16 26 AWG wire Figure 11 Connect visual and audible external indicators For a complete listing of available sensors and accessories go to the product page f...

Page 12: ...Problem Receiving false alert messages from installed ENVIROMUX Liquid Detection sensor E LDx y or E LD LCx y Cause Sensor is in environment with significant electrical noise and is picking up this no...

Page 13: ...a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Drive...

Reviews: