MAN057 Rev Date
5
/7/2018
Sensor Installation Manual
ENVIROMUX
®
Series
E-T / TRHM-E7
Temperature/Humidity sensors
E- LDSx-y
Liquid Detection Sensor
E-BCN-R
Beacon
E-SRN-M
Siren
E-M-DCS3
Door Contact Switch
E-TDS
Tamper Switch
Page 1: ...Date 5 7 2018 Sensor Installation Manual ENVIROMUX Series E T TRHM E7 Temperature Humidity sensors E LDSx y Liquid Detection Sensor E BCN R Beacon E SRN M Siren E M DCS3 Door Contact Switch E TDS Tam...
Page 2: ...e Alert Fix 11 TABLE OF FIGURES Figure 1 Connect sensors to E MINI LXO 2 Figure 2 Liquid detection sensor 4 Figure 3 Terminal block for dry contact sensors 5 Figure 4 Sensors connected by cables with...
Page 3: ...MICRO T RHP E T or TRHM E7 For measuring temperature and humidity the E MINI LXO and E MICRO T RHP uses the E T E7 temperature only E TRHM E7 combination temperature and humidity sensor For high tempe...
Page 4: ...n a 2 25 F 1 25 C Sensor Cable The CAT5 connection cable between the E MINI LXO E MICRO T RHP and the RJ45 Sensors is terminated with RJ45 connectors and must be wired according to the EIA TIA 568 B i...
Page 5: ...oblems after you have cleaned it with isopropyl alcohol or if you think the rope needs a good scrubbing you can clean it with warm soapy water You will have to remove the rope from its installed locat...
Page 6: ...h E M DCS3 Door Contact Sensor E DCS PS2 Plunger Style Door Contact Sensor To install the dry contact sensor s A Attach the positive lead to a terminal corresponding to a marking on the E MINI LXO and...
Page 7: ...ing temperature and humidity sensors to the ENVIROMUX the web interface will identify the sensor accordingly for the type of sensor it is The status bar and configuration page will enter the maximum a...
Page 8: ...ensors for plug in to the RJ45 Sensor sockets the following socket to sensor wiring must be followed RJ45 Sensor Socket Pinout Pin Pin Name 1 GND 2 SENSE 3 RS485 4 5 VDC 5 TAMPER SWITCH 6 RS485 7 12 V...
Page 9: ...NTI ENVIROMUX SENSOR INSTALLATION 8 Figure 8 Basic DIGITAL IN Terminal Connections...
Page 10: ...sure to only apply tape to the ends exposing as much of the sensor as possible At least 5 8 of the sensor must be exposed for it to function See Figure 2 Figure 9 Secure liquid detection sensor with t...
Page 11: ...tention All devices must be installed using 16 26 AWG wire Figure 11 Connect visual and audible external indicators For a complete listing of available sensors and accessories go to the product page f...
Page 12: ...Problem Receiving false alert messages from installed ENVIROMUX Liquid Detection sensor E LDx y or E LD LCx y Cause Sensor is in environment with significant electrical noise and is picking up this no...
Page 13: ...a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Drive...