5. Setting up Z308
5-1. Turn On/ Turn Off Z308
To manually turn on or turn off Z308, please use the following instructions:
A.
Turn it on:
Press and hold the
Panic Button
for 3 seconds. The indicators will flash
once
, and the
device is ready to be used.
y
When ZB02C is in a ZigBee network
→
the indicator will flash
green
5 times
.
B.
Turn it off:
Press and hold the
Panic Button
for 6 seconds. The indicator will flash
red
10 times
within 5 seconds. Within the 5-second period of time, press the
Panic Button
again to turn it off.
5-2. Join the ZigBee Network
After Z308 is turned on, it will search for an existing ZigBee network and send a request to join the network
automatically. While Z308 is under the coverage from a coordinator or a router whose
permit-join feature is
enabled
, Z308 will be permitted to join the network.
Step1. Enable the permit-join function (valid for 60 seconds) of a coordinator or a router (please refer to
the user manual of the coordinator or the router to enable the permit-join feature).
Step2. Turn on Z308. It will start to search and join the network.
Step3. The indicator will flash
green
once
when it finds out a network to join.
Step4. The indicator will flash
green
5 times
after it is joined successfully. Otherwise, the indicator will
not flash.
Step5. When Z308 cannot join a network in 25 seconds, it will go into turn-off mode.
y
After joining a network, Z308 would try to enroll in the ZigBee security system. Please make sure Z308
and CIE (Control and Indicating Equipment) device have enough power.
5-3. Enroll in the ZigBee Security System
Z308 is a Zone device in the ZigBee security system. Right after Z308 join the ZigBee network, it will
automatically find out a CIE (Control and Indicating Equipment) device (i.e. Netvox Z201B) and send a
registration request to the CIE device to enroll in the security system. The enrollment has these 3 situations:
A. There is no CIE device or no compatible CIE device in the network
→
the indicator flashes
red
twice
.
B. There is a compatible CIE device in the network, but it is failed to enroll
→
the indicator flashes
red
4
times
. Users can reboot Z308 to initiate the registration.
C. The enrollment is completed
→
the indicator flashes
red
6 times
.
NOTE: