7
5-4. Sleeping Mode
Z308 is designed to go into sleeping mode for power-saving in some situations:
A.
While the device is in the network
→
the sleeping period is 5 minutes; it will wake up every 5
minutes to keep online.
B.
Once Z308 was joined to a network and by any chance the network is no longer existed or the device
is out of the network
→
Z308 will wake up every 5 minutes to find the network it joined before.
It never keeps in sleeping mode and continues to find out a network every 5 minutes. This condition would
consume up to 30 times power spending compared to normal-operating status. To prevent this unwanted power
consumption, we recommend that users turn off the device.
5-5. Wake up Z308
When users would like to setup or acquire data from the device which is in sleeping mode, we have to wake
up the device as the following steps:
Step1. Press and hold the
Panic Button
for 3 seconds. Release the button when the indicator flashes
red
once
.
Step2. The indicator flashes
green
5 times
when Z308 is online.
Step3. Z308 will broadcast the device data to the ZigBee network.
Z308 would be in active status for 2 minutes for communication.
5-6. Panic Button
y
Z308’s Zone Type: Key Fob (ID: 0x0115)
y
The value of Alarm2 is 1 when sending alarm message.
Under the circumstances that Z308 has enrolled to the security system, it will send the alarm message to the
command center (and the bound devices with ID: 0x0500) after pressing the
Panic Button
. The Warning
Device will send out alarm sound or lighting alert for immediate help.
Under the circumstances that Z308 hasn’t enrolled to the security system, it will try enroll in a security system
after pressing the
Panic Button
. After the enrollment, Z308 will send the alarm message to the command
center.
ZoneStatusChange commands: 0x00.
The command list:
Bits: 8
8
8
var