7
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
Config
ReportReq
R718PQA
0x01
0x97
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed 0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed 0x00)
Set
IRDisableTImeReq
0x03
IRDisableTime
(2bytes Unit:s)
IRDectionTime
(2bytes Unit:s)
Reserved
(5Bytes,Fixed 0x00)
Set
IRDisableTImeRsp
0x83
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
Get
IRDisableTImeReq
0x04
Reserved
(9Bytes,Fixed 0x00)
Get
IRDisableTImeRsp
0x84
IRDisableTime
(2bytes Unit:s)
IRDectionTime
(2bytes Unit:s)
Reserved
(5Bytes,Fixed 0x00)
(1) Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v
Downlink: 0197003C003C0100000000
Device returns:
8197000000000000000000 (configuration succeeded)
8197010000000000000000 (configuration failed)
(2) Read device parameters
Downlink: 0297000000000000000000
Device returns:
8297003C003C0100000000 (device current configuration parameter)
(3) Configure IRDisableTIme and IRDectionTime
IRDisableTime= 30s
、
IRDectionTime= 30s // IRDectionTime >= IRDisableTime
. Downlink: 0397001E001E0000000000
Devices return:
8497000000000000000000 (the configuration is successful)
8497010000000000000000 (the configuration is failed)