background image

                                                                   

  Model

R313CA   

 

 

 

 

Wireless Dry Contact Sensors 

 

 

 

 

 

 

 
 

Wireless Dry Contact Sensor 

 

R313CA 

User Manual 

 

 

 

 

 

 

 

 

 

 

Copyright©Netvox Technology Co., Ltd. 

This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained 

in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX 

Technology. The specifications are subject to change without prior notice. 

 

Summary of Contents for R313CA

Page 1: ...td This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Important Maintenance Instruction 10...

Page 3: ...with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For exampl...

Page 4: ...ters and reading data via the third party software platforms and set alarms via SMS text and email optional Applicable to the third party platforms Actility ThingPark TTN MyDevices Cayenne Note Batter...

Page 5: ...e about 10 seconds After reinserted the battery the device is in the turn on state according to the default If the device has been turned on it does not need to press the button to enter the turn on s...

Page 6: ...rding to the default configuration before any other configuring Report MaxTime Max Interval 3600s Report MinTime Min Interval 3600s Default Every Min Interval will detect the state of the dry contact...

Page 7: ...3CA device parameter MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 014C003C003C0100000000 Device return 814C000000000000000000 configuration success 814C010000000000000000 configuration failur...

Page 8: ...th M 1H 1H 10th M 1H 25th M Wake up and collects data REPORTS 2 8V Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORTS 2 8V Wakes up and collects data 2 8V Does not report Wakes...

Page 9: ...ach the device to the smooth wall please do not stick it to the rough wall to avoid falling off after a longtime usage Note Wipe the wall surface before installation to avoid dust on the wall surface...

Page 10: ...9 Fig Diagram of connecting with the wired smoke sensor R313CA External power supply Wired smoke sensor External power supply...

Page 11: ...batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board...