1. Introduction 

 

The R313CA is a dry contact detection device for Netvox ClassA type devices based on the LoRaWAN open protocol and is 

compatible with LoRaWAN protocol. When any dry contact of R313CA detects a change, R313CA will send a message to the 

gateway. 

 

LoRa Wireless Technology: 

LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other 

communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance. 

Widely used in long-distance, low-data wireless communications. For example, automatic meter reading, building automation 

equipment, wireless security systems and industrial monitoring. Main features include small size, low power consumption, 

transmission distance, anti-interference ability and so on. 

 

LoRaWAN: 

LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and 

gateways from different manufacturers. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for R313CA

Page 1: ...td This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Important Maintenance Instruction 10...

Page 3: ...with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For exampl...

Page 4: ...ters and reading data via the third party software platforms and set alarms via SMS text and email optional Applicable to the third party platforms Actility ThingPark TTN MyDevices Cayenne Note Batter...

Page 5: ...e about 10 seconds After reinserted the battery the device is in the turn on state according to the default If the device has been turned on it does not need to press the button to enter the turn on s...

Page 6: ...rding to the default configuration before any other configuring Report MaxTime Max Interval 3600s Report MinTime Min Interval 3600s Default Every Min Interval will detect the state of the dry contact...

Page 7: ...3CA device parameter MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 014C003C003C0100000000 Device return 814C000000000000000000 configuration success 814C010000000000000000 configuration failur...

Page 8: ...th M 1H 1H 10th M 1H 25th M Wake up and collects data REPORTS 2 8V Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORTS 2 8V Wakes up and collects data 2 8V Does not report Wakes...

Page 9: ...ach the device to the smooth wall please do not stick it to the rough wall to avoid falling off after a longtime usage Note Wipe the wall surface before installation to avoid dust on the wall surface...

Page 10: ...9 Fig Diagram of connecting with the wired smoke sensor R313CA External power supply Wired smoke sensor External power supply...

Page 11: ...batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board...