6
Device
Device
Type
Report
Type
NetvoxPayLoadData
R718KA
0x22
0x01
Battery (1Byte)
unit:0.1V
Current (1Byte)
unit:1mA
FineCurrent (1Byte)
unit:0.1mA
Reserved (5Bytes)
fixed 0x00
Uplink:
01220123074E0000000000
Byte
Value
Attribute
Result
Resolution
1st
01
Version
1
-
2nd
22
DeviceType
22
-
3rd
01
ReportType
1
-
4th
23
Battery
3.5v
23(HEX)=35(DEC),35*0.1v=3.5v
5th
07
Current
7mA
07(HEX)=7(DEC),7*1mA=7mA
6th
4E
FineCurrent
7.8mA
4E(HEX)=78(DEC),78*0.1mA=7.8mA
7th~11th
0000000000
Reserved
0
-
5.2 Example of ConfigureCmd
FPort
:
0x07
Bytes
1
1
Var (Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
Config
ReportReq
R718KA
0x01
0x22
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
CurrentChange
(1byte Unit:1mA)
Reserved
(3Bytes,Fixed
0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)