background image

 

 

 

 

Example#3

 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V 

 

 

 

Notes: 

1)

 

The device only wakes up and performs data sampling according to MinTime Interval. When it is on sleeping mode, it does not 

collect data. 

2)

 

The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, the 

device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device reports 

according to MaxTime interval. 

3)

 

We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up 

frequently and the battery will be drained soon. 

4)

 

Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another cycle of 

MinTime/MaxTime calculation is started. 

 

 

 

 

 

 

                                    

 

MaxTime

 

 

 

 

 

Sleeping(MinTime)      sleeping          

        

sleeping            sleeping

 

 

 

0H

        

         

15

th

 M               30

th

 M            45

th

 M               

1H

                                 

               

2H 

         

 

 

 

 

 

 

 

Wakes up and 

collects data 

3.6V 

Does not report 

 

 

Wakes up and 

collects data 

REPORT 3.6V 

 

Wakes up and 

collects data 

REPORT 3.6V 

Wakes up and 

collects data 

3.6V 

Does not report 

 

 

 

                                                                                                 

  MaxTime 

 

 

 

 

     

sleeping             

sleeping

         

...

 

 

 

0H

             

15

th

 M           

30

th

 M 

         

45

th

 M              1H  

1H 10

th

 M

    1H 25

th

 M           1H 40

th

 M     1H 55

th

 M

      

2H 10

th

 M

             

        

 

 

 

 

 

 

 

Wakes up and 

collects data 

REPORTS 3.6V 

 

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data  

3.5V 

Does not report 

Wakes up and 

collects data 

3.5V   

Does not report 

 

Wakes up and 

collects data 

REPORTS 

3.5V 

Wakes up and 

collects data 

3.6V   

Does not report 

Users push the button,   

REPORTS 3.5V. 

Recalculate 

MaxTime.   

Wakes up and collects 

data 

3.5V |3.5-3.6|=0.1 

REPORTS 3.5V 

Wakes up and 

collects data   3.5V 

Does not report 

 

Summary of Contents for DirekTronik R718KA

Page 1: ...Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other p...

Page 2: ...4 5 Data Report 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 7 6 Information about Battery Passivation 9 6 1 To determine whether a battery requ...

Page 3: ...ods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For examp...

Page 4: ...l object Frequency hopping spread spectrum Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applica...

Page 5: ...een indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network to join The green indi...

Page 6: ...Current Change Reportable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval After power on the...

Page 7: ...7 1mA 7mA 6th 4E FineCurrent 7 8mA 4E HEX 78 DEC 78 0 1mA 7 8mA 7th 11th 0000000000 Reserved 0 5 2 Example of ConfigureCmd FPort 0x07 Bytes 1 1 Var Fix 9 Bytes CmdID DeviceType NetvoxPayLoadData CmdI...

Page 8: ...ortable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleeping MinTime Wakes up and collects data Wakes up and collects data Wakes up and collects data REPORTS 3 6V REPORTS 3 5...

Page 9: ...ng from data variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculation is started MaxTime Sleeping MinTime sleeping sleeping sleeping 0H 15th M 30 th M 45 th M 1H 2H Wak...

Page 10: ...passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from reli...

Page 11: ...tic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device...

Reviews: