background image

v1.0, February 2007

iv

Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22) and EN 
55 024. 

Customer Support

Refer to the Support Information Card that shipped with your Managed Stackable Layer 3 Fast Ethernet Switch.

World Wide Web

NETGEAR maintains a World Wide Web home page that you can access at the universal resource locator (URL)

 

http://www.netgear.com

. A direct connection to the Internet and a Web browser such as Internet Explorer or Netscape are 

required.

Product and Publication Details

Warning: 

This is a Class A product. In a domestic environment, this product may cause 

radio interference, in which case the user may be required to take appropriate 
measures. 

Model Number:

GSM7328S, GSM7352S, and GSM7328FS

Publication Date:

February 2007

Product Family:

managed switch

Product Name:

• ProSafe™ 24-Port 10/100/1000 L3 managed Stackable Switch with 4 

10 Gigabit I/O Slots GSM7328S

• ProSafe™ 48-Port 10/100/1000 L3 managed Stackable Switch with 4 

10 Gigabit I/O Slots GSM7352S

• ProSafe™ 24 Fiber SFP Gigabit Layer 3 managed Stackable Switch 

with 4 10-Gigabit Slots GSM7328FS

Home or Business Product:

Business

Language:

English

Publication Part Number:

202-10255-01

Publication Version Number

1.0

Summary of Contents for GSM7328Sv1 - ProSafe 24+4 Gigabit Ethernet L3 Managed Stackable Switch

Page 1: ...202 10255 01 February 2007 NETGEAR Inc 4500 Great America Parkway Santa Clara CA 95054 USA Managed Stackable Layer 3 Switches GSM7328S GSM7352S and GSM7328FS Hardware Installation Guide...

Page 2: ...10 Gigabit I O Slots GSM7328S has been suppressed in accordance with the conditions set out in the BMPT AmtsblVfg 243 1991 and Vfg 46 1992 The operation of some equipment for example test transmitters...

Page 3: ...ications Cet appareil num rique NETGEAR ProSafe 24 Port 10 100 1000 L3 managed Stackable Switch with 4 10 Gigabit I O Slots GSM7328S respecte les limites de bruits radio lectriques visant les appareil...

Page 4: ...t and Publication Details Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures Mode...

Page 5: ...and LEDs 2 4 GSM7352S Rear Panel 2 6 GSM7328FS Front Panel and LEDs 2 7 GSM7328FS Rear Panel 2 9 Safety Instructions 2 10 Chapter 3 Hardware Installation Package Contents 3 1 Protecting Against Elect...

Page 6: ...the Switch 3 10 RJ 45 Ports 3 10 Connecting a Console to the Switch 3 11 Chapter 4 Troubleshooting Troubleshooting Chart 4 1 Additional Troubleshooting Suggestions 4 2 Appendix A Technical Specificati...

Page 7: ...gement concepts and terminology This guide uses the following typographical conventions This guide uses the following formats to highlight special messages Table 1 1 Typographical Conventions Italics...

Page 8: ...is described in the manual A button to access the full NETGEAR Inc online knowledge base for the product model Links to PDF versions of the full manual and individual chapters Danger This is a safety...

Page 9: ...http www adobe com Printing a PDF Chapter Use the PDF of This Chapter link at the top left of any page Click the PDF of This Chapter link at the top left of any page in the chapter you want to print T...

Page 10: ...and GSM7328FS Hardware Instal 1 4 About This Manual v1 0 February 2007 Revision History Part Number Version Publication Date Description 201 10813 01 1 0 March 2006 Document Created 202 10255 01 1 0...

Page 11: ...naged Stackable Switch with 4 10 Gigabit I O Slots GSM7352S ProSafe 24 Fiber SFP Gigabit Layer 3 managed Stackable Switch with 4 10 Gigabit Slots GSM7328FS These switches can be free standing or rack...

Page 12: ...ly Solid green The redundant power supply is connected and using internal power Solid yellow The switch internal power has failed or been disconnected but the redundant power supply is providing power...

Page 13: ...orts 2 LEDs per port Link ACT LED Off No link is established on the port Solid green A valid link is established on the port Blinking green The port is sending or receiving packets SPD LED Off No link...

Page 14: ...e module bays support any combination of either the ProSafe 10 Gigabit Ethernet XFP Adapter AX741 or the ProSafe 24 Gigabit Stackable Module AX742 GSM7352S Front Panel and LEDs The figure below shows...

Page 15: ...providing power to the switch Blinking yellow The redundant power supply unit is present but the power has failed Off The redundant power supply is disconnected or not present Fan Red Fan has failed O...

Page 16: ...LED XFP Module present LED ACT Off The 10GbE Adapter is not present Solid green The 10GbE Adapter is present Blinking green Packets transmission or reception is occurring on the port Stacking Adapter...

Page 17: ...set button RJ 45 jacks copper fiber combo ports and two module bays The module bays support any combination of either the ProSafe 24 Gigabit Stackable Module AX742 or the ProSafe 10 Gigabit Ethernet X...

Page 18: ...e port Solid Yellow A valid 100Mbps link is established on the port Solid Green A valid 1000Mbps link is established on the port Note If port 21 24 media changes to SFP the jack LED changes to the OFF...

Page 19: ...odule Present LED ACT Off 10GbE adapter absent Solid Green 10GbE adapter present Blinking Green Packet transmission or reception is occurring on the port Stacking Adapter Link ACT LED OFF Stacking mod...

Page 20: ...provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not op...

Page 21: ...marked on the product To help prevent electric shock plug the system and peripheral power cables into properly grounded electrical outlets The peripheral power cables are equipped with three prong plu...

Page 22: ...Managed Stackable Layer 3 Switches GSM7328S GSM7352S and GSM7328FS Hardware Instal 2 12 Introduction v1 0 February 2007...

Page 23: ...ord Rubber footpads for tabletop installation Rubber caps for the SFP sockets Rack mounting kit Null modem serial cable RS 232 with 9 pin connectors NETGEAR CD The CD contains Configuration software D...

Page 24: ...nts in a static safe area If possible use antistatic floor pads workbench pads and an antistatic grounding strap Unpacking the Hardware Check the contents of the boxes to make sure that all items are...

Page 25: ...age immediately Installation Install the equipment in the sequence presented in this chapter as shown below 1 Select a Location See Select a Location on page 3 4 2 Install the Switch See Install the S...

Page 26: ...r source within 6 feet 1 8 meters of the installation location Power specifications for the switch are shown in Appendix A Technical Specifications Be sure that the AC outlet is not controlled by a wa...

Page 27: ...er footpad on each of the four concave spaces on the bottom of the switch The rubber footpads cushion the switch against shock and vibrations Installing the Switch in a Rack To install the switch in a...

Page 28: ...switch The only way to apply or remove power is to connect or disconnect the power cord Before you connect the power cord select an AC outlet that is not controlled by a wall switch which can turn of...

Page 29: ...apters AX741 The modules and adapters are sold separately SPF Modules The module bay accommodates a standard SFP module with an LC connector that is compatible with the IEEE 802 3z 1000BASE X standard...

Page 30: ...stallation The High Speed I O Module Bays support ProSafe 10 Gigabit Ethernet XFP Adapter AX741 or ProSafe 24 Gigabit Stackable Modules AX742 When the ProSafe 10 Gigabit Ethernet XFP Adapter AX741 is...

Page 31: ...or the rear of each switch 2 Connect the provided stacking cable between a pair of AX742 modules in each switch within a stack 3 Connect each switch to the next in a cascade to build the backplane of...

Page 32: ...e switch When the power is off you can remove the cover plate and connect the RPS unit to the switch After all connections are completed apply power to the switch Connecting Equipment to the Switch Yo...

Page 33: ...or UNIX workstation Null modem cable with 9 pin connectors on each end shipped with the product To connect a console to the switch 1 Connect the null modem cable to the console port on the rear of th...

Page 34: ...ed for this purpose Quick Installation Guide Explains basic setup and configuration provided as both a print document and in PDF format on the Resource CD Command Line Interface Reference for the ProS...

Page 35: ...Port connection is not working Check the crimp on the connectors and make sure that the plug is properly inserted and locked into the port at both the switch and the connecting device Make sure that a...

Page 36: ...AC power If the problem continues contact NETGEAR technical support Auto Negotiation The copper 10 100 1000 Mbps ports negotiate the correct duplex mode and speed if the device at the other end of the...

Page 37: ...10000BASE SR 802 3x flow control Switch management Port mirroring support SNMP v1 v2c v3 RFC1757 RMON 1 groups 1 2 3 and 9 RFC1213 MIB II RFC1643 Ethernet Interface MIB RFC1493 bridge MIB RFC2131 DHCP...

Page 38: ...r 24 Gigabit stacking connectivity RS 232 console port 48 RJ 45 connectors for 10BASE T 100BASE TX and 1000BASE T Eight slots are gigabit interface converters SFP for SFP modules Four I O module bays...

Page 39: ...nt Operating temperature 32 to 122 F 0 to 50 C humidity 90 maximum relative humidity noncondensing altitude 10 000 ft 3 000 m maximum Storage temperature 4 to 158 F 20 to 70 C humidity 95 maximum rela...

Page 40: ...Managed Stackable Layer 3 Switches GSM7328S GSM7352S and GSM7328FS Hardware Instal A 4 Technical Specifications v1 0 February 2007...

Page 41: ...Enabled Flow control full duplex Disabled Broadcast storm control Enabled Gigabit port type Auto detect Management IP configuration DHCP Password protection Disabled User name Admin Password none Web...

Page 42: ...ruary 2007 IP routing Disabled RIP Disabled MAC address aging 300 seconds OSPF Disabled SNMP community public read only access private read write access DHCP Server Disabled VLAN Ingress filtering Ena...

Page 43: ......

Page 44: ...NETGEAR Inc 4500 Great America Parkway Santa Clara CA 95054 USA February 2007...

Reviews: