d. Return to admin mode:
set -priv admin
e. You can safely shutdown the node.
3. If the
Key Manager
type displays
external
and the
Restored
column displays anything other than
yes
:
a. Enter the onboard security key-manager sync command:
security key-manager external
sync
If the command fails, contact NetApp Support.
b. Verify that the
Restored
column equals
yes
for all authentication keys:
security key-manager
key query
c. You can safely shutdown the node.
4. If the
Key Manager
type displays
onboard
and the
Restored
column displays anything other than
yes
:
a. Enter the onboard security key-manager sync command:
security key-manager onboard sync
Enter the customer’s onboard key management passphrase at the prompt. If the passphrase cannot be
provided, contact NetApp Support.
b. Verify the
Restored
column shows
yes
for all authentication keys:
security key-manager key
query
c. Verify that the
Key Manager
type shows
onboard
, manually backup the OKM information.
d. Go to advanced privilege mode and enter
y
when prompted to continue:
set -priv advanced
e. Enter the command to display the key management backup information:
security key-manager
onboard show-backup
f. Copy the contents of the backup information to a separate file or your log file. You’ll need it in disaster
scenarios where you might need to manually recover OKM.
g. Return to admin mode:
set -priv admin
h. You can safely shutdown the node.
Shut down the impaired controller - AFF FAS8300 and FAS8700
Option 1: Most systems
After completing the NVE or NSE tasks, you need to complete the shutdown of the impaired node.
Steps
1. If the impaired node isn’t at the LOADER prompt:
If the impaired node displays…
Then…
Waiting for giveback...
Press Ctrl-C, and then respond
y
when prompted.
14