NetApp DE460C Replacing Manual Download Page 2

Before you begin

You have obtained the following items:

Antistatic protection

Attention: 

Possible hardware damage – To prevent electrostatic discharge damage to the drive shelf, use proper

antistatic protection when handling drive shelf components.

Replacement drive drawer

Replacement left and right cable chains

Flashlight

Permanent marker

You have installed SANtricity System Manager on a management station, so you can use the storage array's command
line interface (CLI)

Note: 

If this software has not yet been installed, follow the instructions in the 

SANtricity System Manager Express

Guide or the SANtricity Power Guide for Advanced Users for your operating system to download and install it.

Steps

1. 

Preparing to remove a drive drawer

 on page 2

2. 

Removing the cable chains

 on page 5

3. 

Removing a drive drawer

 on page 10

4. 

Installing a drive drawer

 on page 13

5. 

Attaching the cable chains

 on page 14

6. 

Reinstalling the drives

 on page 18

Related information

SANtricity System Manager 11.40 Installing and Configuring for Linux Express Guide
SANtricity System Manager 11.40 Installing and Configuring for VMware Express Guide
SANtricity System Manager 11.40 Installing and Configuring for Windows Express Guide
SANtricity 11.40 Installing and Configuring for Linux Power Guide for Advanced Users
SANtricity 11.40 Installing and Configuring for VMware Power Guide for Advanced Users
SANtricity 11.40 Installing and Configuring for Windows Power Guide for Advanced Users

Preparing to remove a drive drawer

If the drive shelf is powered on, you must issue the 

Set Drawer Service Action Allowed Indicator

 CLI command to

prevent the controller from accessing the drive drawer. This command also allows you to determine if the drives in the drawer
are in volume groups or disk pools protected by Drawer Loss Protection. If the command fails, you will need to power off the
controller shelf before replacing the drawer.

Before you begin

Before issuing the CLI command, confirm that the drive shelf meets all of these conditions:

The drive shelf cannot be over temperature.

Both fans must be installed and have a status of Optimal.

All drive shelf components must be in place.

2

Summary of Contents for DE460C

Page 1: ...at have Drawer Loss Protection you can perform this procedure online Otherwise you must stop all host I O activity and power off the shelf before replacing the drive drawer This procedure applies to t...

Page 2: ...r 11 40 Installing and Configuring for Linux Express Guide SANtricity System Manager 11 40 Installing and Configuring for VMware Express Guide SANtricity System Manager 11 40 Installing and Configurin...

Page 3: ...Type this command on the command line and press Enter SMcli ctlr_IP1 p array_password c set tray trayID drawer drawerID serviceAllowedIndicator on Command Description ctlr_IP1 The identifier of the c...

Page 4: ...t Attention Possible data loss If you continue this procedure while I O operations are occurring the host application might lose data because the storage array will not be accessible 5 If the storage...

Page 5: ...Antistatic protection Attention Possible hardware damage To prevent electrostatic discharge damage to the shelf use proper antistatic protection when handling shelf components Flashlight About this t...

Page 6: ...t might overheat 3 Determine which cable chain to disconnect If the power is on the amber Attention LED on the front of the drawer indicates the cable chain you need to disconnect If the power is off...

Page 7: ...the right cable chains from its corresponding vertical guide rail Attention Possible hardware damage If the drive tray is powered on the cable chain is energized until both ends are unplugged To avoi...

Page 8: ...able chain connector within the vertical guide rail Attention Possible hardware damage If the drive tray is powered on do not allow the cable chain connector to touch the metal chassis 6 Disconnect th...

Page 9: ...ight fan canister a Slide the fan canister all the way into the shelf b Move the fan canister handle until it latches with the orange tab c If the drive shelf is receiving power confirm that the amber...

Page 10: ...e the left fan canister If the drive shelf is receiving power confirm that the amber LED on the back of the fan is not illuminated and that air is coming out the back of the fan The LED could remain o...

Page 11: ...removing it 5 Remove the drives from the drive drawer a Gently pull back the orange release latch that is visible on the center front of each drive The following image shows the orange release latch...

Page 12: ...0 11 Orange release latch for drive 11 b Raise the drive handle to vertical c Use the handle to lift the drive from the drive drawer d Place the drive on a flat static free surface and away from magne...

Page 13: ...drawer into the empty slot installing the drives and replacing the front bezel Before you begin You know where to install each drive You have obtained the following items Replacement drive drawer Flas...

Page 14: ...when pushing the drawer closed for the first time Attention Risk of equipment damage Stop pushing the drive drawer if you feel binding Use the release levers at the front of the drawer to slide the d...

Page 15: ...Callout Cable chain Connector Connects to 1 Left Vertical Midplane 2 Horizontal Drive drawer Attaching the cable chains 15...

Page 16: ...ot remove both fans at the same time Otherwise the equipment might overheat 3 Attach the right cable chain a Locate the horizontal and vertical connectors on the right cable chain and the correspondin...

Page 17: ...are latched Attention Risk of equipment malfunction If the connectors are not latched the cable chain might come loose during drawer operation 4 Reinstall the right fan canister If the drive shelf is...

Page 18: ...ction If the connectors are not latched the cable chain might come loose during drawer operation 8 Reinstall the left fan canister If the drive shelf is receiving power confirm that the amber LED on t...

Page 19: ...The figure shows the right side view of a drive showing the location of the raised buttons 1 Raised button on the right side of the drive f Lower the drive straight down making sure the drive is pres...

Page 20: ...ns is off Replaced a drive drawer in an expansion drive shelf without Drawer Loss Protection a Turn on both power switches on the drive shelf b Confirm that both fans come on and that the amber LED on...

Page 21: ...Flash Accel Flash Cache Flash Pool FlexArray FlexCache FlexClone FlexPod FlexScale FlexShare FlexVol FPolicy Fueled by SolidFire GetSuccessful Helix Design LockVault Manage ONTAP MetroCluster MultiSto...

Page 22: ...Fax 1 408 822 4501 Support telephone 1 888 463 8277 22...

Reviews: