CAUTION:
The power supply is short. Always use two hands to support it when removing it from the controller
module so that it does not suddenly swing free from the controller module and injure you.
Blue power supply locking tab
Power supply
5. Using both hands, support and align the edges of the power supply with the opening in the controller
module, and then gently push the power supply into the controller module until the locking tab clicks
into place.
The power supplies will only properly engage with the internal connector and lock in place one way.
To avoid damaging the internal connector, do not use excessive force when sliding the
power supply into the system.
6. Reconnect the power supply cabling:
a. Reconnect the power cable to the power supply and the power source.
b. Secure the power cable to the power supply using the power cable retainer.
Once power is restored to the power supply, the status LED should be green.
1. After you replace the part, you can return the failed part to NetApp, as described in the RMA
instructions shipped with the kit. Contact technical support at
, 888-463-8277 (North
America), 00-800-44-638277 (Europe), or +800-800-80-800 (Asia/Pacific) if you need the RMA number
or additional help with the replacement procedure.