IQ13 Aperture Size
360mm Min
415mm
570mm
Technical Data, Intermittent Operation
Model
Heat
Output
Wood
Refuelling
Interval
Wood
Energy
Efficiency
Wood
Heat
Output
Smokeless
Coal**
Refuelling
Interval
Smokeless
Coal**
Energy
Efficiency
Smokeless
Coal**
IQ13 Wood
5 kW
0.70 hr
77.1% Net
70.2% Gross
IQ13 Multifuel
5 kW
0.70 hr
77.1% Net
70.2% Gross
3.5 kW
1.05 hr
82.8% Net
75.4% Gross
Technical Data, Continuous Operation
Model
Heat
Output
Wood
Refuelling
Interval
Wood
Energy
Efficiency
Wood
Heat Output
Smokeless
Coal**
Refuelling
Interval
Smokeless
Coal
Energy
Efficiency
Smokeless
Coal
IQ13 Wood
5.4 kW
1.45 hr
83.4% Net
75.9% Gross
IQ13 Multifuel
5.4 kW
1.45 hr
83.4% Net
75.9% Gross
3.5 kW
4 hr
78.3% Net
71.2% Gross
General Technical Data
Model
Model
Number
Weight KG
Flue
Draught
Nominal
Flue Gas
Mass Flow
g/s
Flue Gas
Temperature
Down Stream of
Flue Spigot
Free Air
Requirement
IQ13 Wood
IQ13*
108
12pa
4.9
350
0
c
0mm²**
IQ13 Coal
IQ13*
108
12pa
3.8
210
0mm²**
** Free Air Requirement
Air requirement equivalent area. Building regulations Document J, advises that an air supply,permanently open
vents, should be installed for appliances:
If design air permeability >5.0m³/(h.m²) then 550mm²/kW of appliance rated output above 5kW
or
If design air permeability <5.0m³/(h.m²) then 550mm²/kW of appliance rated output.
Equivalent air is as measured according to the method in BS EN13141-1:2004.
It is unlikely that a dwelling constructed prior to 2008 will have an air permeability of <5.0m³/(h.m²) at 50pa
unless extensive measures have been taken to improve air-tightness.