24
operation by SMS
SUMMary of SMS opEraTING CoMMaNDS. The following examples use the default Master
Code of 123 just as an example. Substitute your own valid user code/s in operation.
opEraTIoN
SMS To ThE
paNEL
SMS rEpLy
arM
a123E
a123E aCK
arming status: arEa 1 arMED
IN EXIT DELay
zones unsealed: NoNE
zones in alarm: NoNE
zones excluded: NoNE
outputs status: aLL off
any unsealed zones, zones in alarm and excluded
zones will listed as ZoNE [x] or by name if named.
DISarM
123E
123E aCK
[plus zones and outputs
status as per arming response
above]
hoME mode
h123E
h123E aCK arming status: arEa 1
arMED IN EXIT DELay
[plus zones and outputs status as
per arming response above]
EXCLUDE zones
(Example zones 4 & 5)
X123E4E5E
X123E aCK 4E aCK 5E aCK E aCK
zones excluded: ZoNE 4 ZoNE 5
fIrE alarm
1
(Triggers the fire alarm, if enabled)
f123E
f123E aCK
MEDICaL alarm
2
(Triggers Medical alarm, if enabled)
D123E
D123E aCK
paNIC alarm
3
(Triggers panic alarm, if enabled)
S123E
S123E aCK
operate aUX outputs, eg aux1 (if
enabled for use)
(aux2 is 22, aux3 is 33 etc)
C123E11oN
C123E11off
11* aCK auxiliary outputs on: aUX1
11# aCK auxiliary outputs on: aLL off
[or the aux number/s if any are on]
1
The fIrE alarm sounds the siren using the fIrE siren sound and sends a fire report if programmed.
2
The MEDICaL alarm triggers the strobe light if programmed and sends a medical report if programmed.
3
The paNIC alarm triggers the sirens and strobe if programmed.