background image

 

User Manual   

Ness IQ-MDVR-8 

GUI     

 

Mobile Digital Video Recorder 

 

 

 

Summary of Contents for IQ-MDVR-8

Page 1: ...User Manual Ness IQ MDVR 8 GUI Mobile Digital Video Recorder ...

Page 2: ...rove its products All specifications are therefore subject to change without any notice The purpose of this manual is to kindly aid the user for the operation for our MDVR especially for GUI setting The user should have a basic understanding of computer operation and basic knowledge of how to connect peripherals and make some settings ...

Page 3: ...ol 5 3 GUI Tree 8 4 System Start Up 9 5 GUI Configuration 11 5 1 SEARCH 11 5 1 1 REC SEARCH 11 5 1 2 EVENT SEARCH 14 5 2 SETUP 15 5 2 1 SYSTEM 16 5 2 2 RECORD 23 5 2 3 NETWORK 30 5 2 4 EVENT 34 5 2 5 PERIPHERAL 40 5 3 INFORMATION 41 5 3 1 SYSTEM 42 5 3 2 HISTORY 42 5 3 3 MODULES 43 ...

Page 4: ...isplay synchronously Mirror recoding makes the hard disk and SD card recording at the same time with same frame same resolution and same image quality Maximum 1 hour pre recording and 30 minutes post recording Watermark prevents any modification in recorded file which is part of the law enforcement Better Compression rate at H 264 50 less than MPEG4 Enhance recording storage rate in most efficienc...

Page 5: ... Keys Use the numbers to input Values in the system setup Screen or switch through the channels in QUAD view Navigation Arrows Use the ARROW keys to move between selections input fields and icons Press ENTER to select And EXIT to return and and entering into the OSD screen to check the MDVR working status Next and previous is also used to increase or decrease volume when at live or search screens ...

Page 6: ...e MDVR in to sleep mode You can press power button again to let MDVR start up when it in sleep mode Switch full screen of one channel to quad view Brightness contrast color adjustment for per channel Use button to change the values You have to adjust the values for each channel individually SETUP Login GUI to setup the parameters EXIT Return to the previous menu Stop Used to stop the recording man...

Page 7: ...e CF No use at present F1 Export all the event record files of the day to USB by press F1 key F2 F3 F4 Reserved for future use 4 PTZ Function Key IQ MDVR can support PTZ camera by the protocol PALCO D or PALCO P While the MDVR is connected the PTZ camera by RS485 signal on the RS232 485 expand box following commands can control PTZ ZOOM IN ZOOM OUT ZOOM IN OUT IRIS IRIS Brightness control FOCUS FO...

Page 8: ...Ness IQ MDVR 8 8 3 GUI Tree Graphic User Interface over view ...

Page 9: ... ignition and the unit will automatically start up Power is normally supplied to the MDVR as long as the vehicle ignition is ON Display only view of the cameras is immediately available to be viewed in quad view Normally the power supply for MDVR is about 12V 3A without any accessories System Login for Setup When Password is set disable press SETUP key on the handheld controller into the setup men...

Page 10: ...sing the password and modifies the MAC address DEVICE NO The unit ID of MDVR You can setup the ID for the MDVR in the menu yourself After setting the ID number will appear automatically on the login screen It s the number in the bracket PASSWORD Enter the admin password or user password Keyboard Press Enter to use keyboard to type device ID and password 1 0 9 number key press Enter to select the n...

Page 11: ...ow all the main functions for MDVR including SEARCH SETUP and INFORMATION Search is for searching all the video files and alarm files Setup for all the configurations for MDVR and information display the MDVR and accessory working status 5 1 SEARCH 5 1 1 REC SEARCH You can search all the video files including normal files alarm files by record time and file type Please highlight the option REC SEA...

Page 12: ... and time CHANNEL As IQ MDVR support 8CH so you have to choose the first 4 channels or next 4 channels when you want to playback VIDEO FILE STATUS GREY mean there is no video file of this channel GREEN means the file is normal file RED means alarm YELLOW means the file is alarm file and locked START TIME and END TIME This time schedule is for both playback and export and you have to choose the cha...

Page 13: ...o files to external storage device for playback easily Just please setup the start time and end time for the video from certain channel for local playback Or you can export the file during certain period to thumb driver or any external storage device and backup to computer for playback but the file is H 264 file Please connect the external storage device with MDVR by USB port and then press EXPORT...

Page 14: ...ck for example the video type of record files is NSTC now the video type is PAL you can t playback the video file until you change the video type to NSTC For example If the MDVR recorded by PAL and created video file Then when you reboot up the MDVR and you want to playback the video file recorded by PAL When the MDVR reboot up the video type will change to be NTSC automatically 5 1 2 EVENT SEARCH...

Page 15: ...other files for backup or not EVENT NAME The OSD for the alarm such as the alarm for video loss I O sensor alarm for over speed low speed or high temperature and so on DATE Display the date when the alarm occurred TIME The start time when the alarm occurred REC if there is an R means it has the corresponding video files otherwise it doesn t have REV Press for selecting all or not For example if yo...

Page 16: ...he GPS the MDVR device must have GPS connection Should have GPS module and antenna and GPS must can receive the signal When the system time arrives the sync time MDVR unit will synchronize with GPS time once B While selecting the NTP Network Time Protocol the device must have network access connection and assign the NTP IP location TIME ZONE Please choose the correct time zone for MDVR system SYNC...

Page 17: ...e setting is timer from 5 00 12 00am so the MDVR will work during his period but for recording it depends on the setting on the SCHEDULE and RECORD MODE menu A IGNITION for start up and shut down delay function For example If it s Ignition mode it will start up when ignition is on and if the shut down delay time is 5 min then MDVR will shut down after 5 min after the ignition off B TIMER MDVR will...

Page 18: ... 3 and 9 6 two options TRANSPARENCY Setup the brightness for the screen display as you want Scroll to SAVE to make the setting valid C REGISTER INFO UNIT S N The series number for MDVR One MDVR has only one S N This number is read from special encrypted chip UNIT ID Device ID Use the NUMERIC keypad to enter the system ID from 00000 to 99999 This ID is used when logging in to the unit if security i...

Page 19: ...ou want to format hard disk please select video storage and if you want to format SD card for mirror please select SD FUNCTION FAST FORMAT SLOW FORMAT and HDD DETECT FAST FORMAT is the same as quick format on PC SLOW FORMAT means it will check whether the HDD have bad sectors if have it will remember and won t write data here again and it will delete all the video files DETECT HDD means it will ch...

Page 20: ...to the USB port on the front panel of MDVR 3 Please enter into this interface select firmware option and press UPGRADE MDVR will upgrade the firmware automatically Please make sure you do not remove the thumb driver or cut of the power for the MDVR during upgrading the firmware as this is very easily to damage the FLASH for MDVR 4 During the firmware upgrade then following screen will pop up 5 Aft...

Page 21: ...ctive this function or not Selecting ON will require a password in order to access the setup menu Selecting OFF will not require a password in order to access the setup menu USER PASSWORD User can only search can t modify any parameters ADMIN PASSWORD An Administrator with full rights Re enter must be same input as first password otherwise the system would not accept the password setting when pass...

Page 22: ...nfiguration file to the current device except MAC address and IP Please insert the external storage device to the USB port Must have configuration file in the storage device and then press IMPORT The configuration will import to another MDVR automatically RESTORE Restore all the settings to factory default settings F SYSTEM LOG You can export or delete the user log in this interface as follow pict...

Page 23: ...e create details please check the manual from CMS instruction Also you can export the config file from another MDVR and then import to another MDVR Remark Geo fencing means you can setup a special area for the vehicle when the vehicle enters into or out of this area it will trigger the alarm and you can do all the configurations in CMS software 5 2 2 RECORD Setup the related configuration for Reco...

Page 24: ...ess space of hard drive BUT when event is trigged MDVR will record according to setup of RECORD SETTING RECORD FILE TIME MIN Recording file packing size 15 30 45 60 minutes optional ALARM DURATION 3 30 SEC The alarm duration time all the alarm for same type considered to be one alarm during the setting for alarm duration and MDVR reset the duration time automatically For example if the setting for...

Page 25: ...ime For SD card if the space less than 1G it will start to delete the files until the space more than 4G OFF Device will stop recording when hard drive space is full less than 2G you must replace an HDD or delete recording file manually then it will start to record LOCKED FILE RETENTION DAY For the MDVR video files you can lock or unlock them Lock function is only for the event alarm files as they...

Page 26: ...MPERATURE Display the temperature on OSD FIRMWARE VERSION Display the current firmware version GPS Display the GPS information fixed means it will display the information always just like date time CHANNEL NAME Display the channel name VEHICLE NO Display the vehicle NO RECORD is ON means it will record the date time channel name and vehicle NO into the record files If all the options are ON Then t...

Page 27: ...splay it in QUAD view ROUND Means channel loop function sequence if you setup time as 5 second which means the channel will switch to full screen from channel 1 to 4 IP INTERCOM This is the enable switch for interphone function which can realize two way audio speak to center server 3G network SIM card and this function must works with CP3 which has a microphone belong to LIVE AUDIO enable or disab...

Page 28: ...s the best Normal quality is the quality for normal record and alarm quality is for alarm record E SUB STREAM Sub stream is the settings for 3G wireless transmission you can setup the bandwidth and enable the channels and otherwise it can t transmit the live video to PC software center server The setup interface as follow BAND WIDTH Setup the band width for the sub stream which due to the network ...

Page 29: ...ording Timer timing recording Schedule 1 2 Press the RIGHT ARROW key to enter values using the NUMERIC keypad into any time field Schedule 1 is the first of two possible ON OFF cycles that apply to any day in the period chosen under Date Schedule 2 is the second cycle for any day in the period There is no need to overlap times of Schedule 1 and Schedule 2 Ending at 23 59 of one day and beginning w...

Page 30: ... can speak to center server please check the details in CP3 manual EXPORT MINIPLAYER This option is for user to export Miniplayer For the details about Minplayer please check the instruction for Miniplayer 5 2 3 NETWORK A LOCAL Local IP is the IP setting for the MDVR to make sure that MDVR can go online Must enter a fixed IP address to use Network capabilities please consult with local Internet Se...

Page 31: ...here are two center servers you can setup that mean you can connect MDVR via WIFI or CABLE and 3G at the same time NET OPTION There are three options one is WIFI one is cable network and the other is MOBILE NETWORK Please select the correct option when create the connection MESSAGE SERVER This server IP must be the IP of the PC that installed message server when you want to create CMS connection Y...

Page 32: ... you call the phone number of the SIM card or send the message to the SIM it will active the wireless module and start to dial up SENSOR means you can setup one sensor to active the wireless module only when you triggered the sensor the wireless module will start to dial up and then connect to internet DIAL PARAMETER settings for SIM Card please check the setup as follow form ...

Page 33: ...all please enable this function here Remark if you want to make a call you need to use our CP3 and speaker D FTP SETTINGS Setup the FTP security for MDVR Take the MDVR as the FTP server so when login with USER NAME and PASSWORD you can download the video files ...

Page 34: ...will also display in live view Please press Enter into the soft keyboard The label also identifies the type of event when doing a quick search using EVENT SEARCH option SET LOW normal close means high to low trigger the alarm HIGH normal open means low to high trigger the alarm ALARM Press ENTER to select between OFF or ON ON means when sensor triggered alarm LED will flashing until re login the s...

Page 35: ...ent does not erase during the over write process of hard disk NEXT PAGE Sensor trigger action means setup the alarm linkage for each sensor for example you setup the ch1 as the alarm linkage for sensor1 when sensor1 triggered ch1 will change to full screen And the device will response the trigger by PRI sensor1 is highest sensor8 is lowest 3G ACT means you can define a sensor to active the 3G modu...

Page 36: ...er this output OFF means can t C SPEED Setup the alarm for over speed and some other parameters SOURCE MDVR is capable of capturing vehicle speed via GPS antenna or Vehicle speedometer Browse between the settings of GPS or speedometer from the list ...

Page 37: ...ate the second area HZ set as first area data 80 SPEED UNIT MPH or KPH MILEAGE is the total mileage that the MDVR has run OVER SPEED If the vehicle exceeds the SPD MDVR will trigger the alarm signal when the following option ALARM set as YES until the driver slows down the speed LOW SPEED If the vehicle exceeds the high speed limit MDVR will trigger the alarm signal when the following option ALARM...

Page 38: ...arm information from camera There are three statuses for camera alarm blind detect motion detect and video loss CH ID please choose the channel you want to setup for motion detect and blind detect SENSITIVE this is the detect sensitivity 1 is the most sensitive M D AREA this option is for user to setup the detect area as follow blank square means the area is selected please back to the setup inter...

Page 39: ...on t start up even the voltage is arrival if the shutdown mode is not low voltage protection mode INTERVAL TIME FOR CMS means when MDVR in low voltage for so long time device will disconnect to CMS server automatically SHUTDOWN DELAY means when MDVR in low voltage for so long time device will shutdown automatically H EMERGENCY EVENT This alarm is triggered by the driver the control panel will be i...

Page 40: ...Ness IQ MDVR 8 40 Trigger alarm when driving resting for a long time 5 2 5 PERIPHERAL A PTZ ...

Page 41: ...ce to select the default setting is none ADDRESS Fill the code of respective PTZ B EXT COM SETUP This interface is for external accessory connection such as control pane PTZ Inertia sensor LED screen station announcement and so on MODE There are STANDARD and BUS MODE two options when select standard mode you can select each external port for each COM when select Bus mode COM1 is station announceme...

Page 42: ...on HDD status and SD card information 1 NO HDD means No HDD installed or the HDD is defective and can not work 2 NO FORMAT means HDD installed but not formatted 3 showing the detailed information for HDD means HDD works fine 5 3 2 HISTORY The data for history information ...

Page 43: ...Ness IQ MDVR 8 43 Press CLEAR to delete all the current data 5 3 3 MODULES Display the GPS WIFI module information ...