J-16 Programmable Outputs
See Note 1
& Note 5
Lighting
Interface Conn.
J4
1 WAY
(PL513/PSC04)
Select PLC Mode
2 WAY
(TW523/PSC05)
JP2
.
N
N
OC
2
32
S
R
J5
Voice & Siren
Dry Contact Relay
3
T
UO
1
T
UO
N/C
COM
N/O
2
T
UO
RED
BLACK
WHITE
GREEN
+VAUX
+12VDC Auxiliary
Power (3)
1.25 Amp PTC
protected
Z1
NEG
Z2
Z3
NEG
Z5
NEG
Z7
Z6
Z4
NEG
Z8
Z9
NEG
Z10
Z11
NEG
Z13
NEG
Z15
Z14
Z12
NEG
Z16
+SAUX
NEG
+VAUX
NEG
+VAUX
NEG
+VAUX
NEG
AC
16.5 V
AC
+VKP
DATA B
DATA A
NEG
OUT 16
OUT 15
OUT 14
OUT 13
OUT 12
OUT 11
OUT 10
OUT 9
OUT 8
OUT 7
+12V
NEG
T1
R1
RING
TIP
Aux Data Bus
Serial Port for
J3
B
A
-
C
+
Audio Network Interface
1
Keypad &
Data Bus
J2 J1
16 Zones expandable to 208
DO NOT
Connect to
a Phone
Line!
Not Used
BATTERY
ON
SW1
+
-
12V Battery
7 to 18 Ah
See Note 3
See Note 4
+ SAUX
+12VDC Switched
Smoke Power
1.1 Amp PTC
protected
NEG
DATA B
+12V
3P
J
LED indicates OUT3 is on
Example wiring for strobe
100-171
Speaker
Jumper to start with
no AC - See Note 7.
Power
Status
Reverse
Bat Leads
NORMAL
ZONE 16
JP1
SMOKE
2WIRE
TELCO SEIZED
DIALLER ACTIVE
1
N.C.
N.O.
ZONE
2200
Ohm
EOL
2
N.C.
N.O.
ZONE
2200
Ohm
EOL
3
N.C.
N.O.
ZONE
2200
Ohm
EOL
4
N.C.
N.O.
ZONE
2200
Ohm
EOL
5
N.C.
N.O.
ZONE
2200
Ohm
EOL
6
N.C.
N.O.
ZONE
2200
Ohm
EOL
7
N.C.
N.O.
ZONE
2200
Ohm
EOL
8
N.C.
N.O.
ZONE
2200
Ohm
EOL
9
N.C.
N.O.
ZONE
2200
Ohm
EOL
10
N.C.
N.O.
ZONE
2200
Ohm
EOL
11
N.C.
N.O.
ZONE
2200
Ohm
EOL
12
N.C.
N.O.
ZONE
2200
Ohm
EOL
13
N.C.
N.O.
ZONE
2200
Ohm
EOL
14
N.C.
N.O.
ZONE
2200
Ohm
EOL
15
N.C.
N.O.
ZONE
2200
Ohm
EOL
16
N.C.
N.O.
ZONE
2200
Ohm
EOL
DATA A
+
-
+
-
See Note 2
Data Bus Terminating Resistor
See Note 1.
Data Bus
See Note 1
J7
1.25 Amp PTC
protected
1
1
Cross Platform Control
PSC05 or
Equivalent
O - I - B A +
(Supervised)
TM
Computer/NESSRP
Ness M1
NEG
+VAUX
+
www.ness.com.au
Serial number located below on base.
Horn speaker*
or 12V siren
*Default
PH
ONE
LI
N
E
H
O
U
SE
PH
ONE
S
Red
Yellow
Mode 3
socket
Green
Black
1
52
6
NOTICE: ADSL broadband can interfere with
the operation of your alarm dialler. It is
recommended that a quality ADSL filter be
installed as per the filter's installation
guidelines.
Use Ness ADSL Filters 100-044 or 100-045.
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
. Maximum COMBINED continuous
current drain from terminals
+SAUX,
+VAUX, +VKP, OUT2 and J16 is 1.5A. Under
alarm the combined outputs should not
exceed 2.5A
. OUT 1 is for speakers 4 to 8 Ohms.
If using more than 2 speakers, use
series/parallel wiring to avoid going below a
4 ohm total load.
. OUT 2 may be set for speaker OR
voltage. Speaker Mode is set by default. In
Speaker Mode avoid going below 4 ohms
total load. In Voltage Mode (switched to
ground, 1A max.) use a 12V siren or
screamer. OUT 2 is supervised against open
circuit (in both Speaker and Voltage modes).
If not used, install a 2.2k Ohm resistor across
the terminals to avoid Output 2 Trouble
condition.
. OUT 3 is a NO/NC dry contact relay
rated 5A.
. OUT 7 to 16 are +12V switched
POSITIVE VOLTAGE outputs rated at 50mA
max.
. Do not connect any neg terminal to
earth ground.
. If AC fails, low battery disconnect
shuts down the control at 10.2 volts. To start
the control with a good battery and no AC,
short the silver pads momentarily. Replace
the battery every 3-5 years and test it
regularly with the NESS-BLT Battery Life
Tester.
Testing of this system should be performed
regularly. Control panel specifications are subject
to change without notice. Figures not to scale.
Document Part No. 440-426
17VDC 3A power
supply. Non-polarity