R E P A I R
7. Cut through both hoses (H) on the same level near the opening of the extraction
head.
The flat receptacles have a special connector latching.
Press down lever at first, then pull receptacle.
20 mm
H
A H-connector
with clips is neces-
sary for re-assembly.
Do not cut through the hoses near the electronic main board!
After re-assembly the metallic clips of the H-connector can get in
contact with electronic components and cause malfunctions.