5
Brütsch/Rüegger Werkzeuge AG, Heinrich Stutz-Strasse 20, Postfach, CH-8902 Urdorf, Tel. +41 44 736 63 63, Fax +41 44 736 63 00, www.neriox.tools, [email protected]
Brütsch/Rüegger Werkzeuge AG, Heinrich Stutz-Strasse 20, Postfach, CH-8902 Urdorf, Tel. +41 44 736 63 63, Fax +41 44 736 63 00, www.neriox.tools, [email protected]
Operation
• Clean the surface of the column, base (1) and scribing needle (19). Fix the scribing needle to the base (17) with the bracket (18).
• Clean the work surface and place the height gauge on it. Activate the ON button (14). Loosen the lock (6) and fastening screw (7) and move
the slider via the handwheel (3) to check for correct function of the display (12).
• To move the slider, turn the handwheel (3). Normally, the locking handle (6) should be in the front, i.e. loose, position;
push it back to lock the slider. When using the fine adjustment mechanism (8), the locking lever must be loosened and the
fastening screw (7) must be tightened.
• Presetting the starting point of the measurement. The work surface is usually the zero point of the measurement. For this, carry out the
following steps:
Move the scribing needle (19) lightly over the work surface (measurement force approx. 3-5-N); the display should show 0, if not activate the
ON/ZERO button (14) to apply the zero position. It is also possible to set a preset value in the plus or minus range with ADD+ (15) and SUB- (16).
Repairs
Should the instrument need to be repaired, please contact our Service Centre → [email protected]
Errors and how to fix them
Error
Possible causes
Solution
Flashing digits
Low voltage
Replace battery
No display
Low voltage
Replace battery
Poor contacts
Correct battery fit, clean contacts
Constant values
Fault in circuit
Remove battery, wait for one minute and reinsert
Replacing the battery
An abnormal display (flashing digits or no display) indicates
a weak battery that must be replaced. To do this,
remove the battery compartment cover in the direction shown by the
arrow and replace the battery with a new SR44W/1.55V battery.
Note
• The positive pole of the battery must face outward.
• After replacing the battery, reset the zero point of measurement.
MAN_BR
W
_vers.
July. 1
9_art. BR
W
137781
Technical data
Measuring range
0-300 mm / 0-600 mm (depending on model)
Resolution
0.01 mm
Repeat accuracy
0.01 mm
Max. reaction speed
1 m/s
Power supply
SR44W button cell, voltage 1.55 V
Operating conditions
Temperature 5-35 ° C, relative humidity <60%
Button functions
OFF
Switch off display
ON/ZERO
Activate display and set zero point
mm/inch
Set mm or inch
ADD+
Preset value plus
SUB-
Preset value minus