be soaked in a vinegar and water solution to remove calcium or hardwater mineral
deposits. Gently clean and dry the O-ring with a cloth, then apply a light coating of
silicone grease.
To reassemble the COR pump:
1.
Carefully position the O-ring on the circular ridge on the pump body
(see image
below)
2.
Position the pump body so the impeller cavity is up.
3.
Slip the impeller assembly down into the pump body until it is fully seated,
ensuring that the 3 keys in the impeller plate are aligned with the corresponding
slots in the pump body
(see image below)
4.
While continuing to hold the pump pointing up, position and seat the volute over
the face of the pump body
5.
Holding the volute firmly against the pump body, then set the pump down on its
base
6.
Reinstall the 4 screws. Tighten the screws just enough to hold the volute snugly
in place against the pump body;
do not overtighten.
Properly
positioned
O-ring
Impeller
alignment key
& slot