Neomatica, LLC. Terminal ADM700 3G GLONASS/GPS. Ed. 7.2, dd. 24.11.2018
30
Requested data code Field 1
Field 2
0x14
Accumulated fuel amount in supply
chamber in “overload” mode, 0.01 l
Accumulated fuel amount in supply
chamber
in “cheat” mode, 0.01 l
0x15
Accumulated fuel amount in backward
chamber in idle mode, 0.01 l
Accumulated fuel amount in backward
chamber in nominal mode, 0.01 l
0x16
Accumulated fuel amount in backward
chamber i
n “overload” mode, 0.01 l
Accumulated fuel amount in backward
chamber
in “cheat” mode, 0.01 l
0x17
Idle mode duration, sec
Nominal mode duration, sec.
0x18
«Overload” mode duration, sec
“Cheat” mode duration, sec
0x19
Negative mode duration, sec
-------------
0x1A
Supply chamber idle mode duration, sec Supply chamber nominal mode
duration, sec
0x1B
Supply chamber “overload” mode
duration, sec
Supply chamber “cheat” mode
duration, sec
0x1C
Backward chamber idle mode duration,
sec
Backward chamber nominal mode
duration, sec
0x1D
Backward chamber “overload” mode
duration, sec
Backward chamber “cheat” mode
duration, sec
0x1E
“Intervention” mode duration, sec
Sensor work duration, sec
7.4.3 Working with RFID-reader ADM20
The tracker allows for a simultaneous connection of up to 5 RFID-readers ADM20 to the RS-
485 bus together with other devices. An example of a simultaneous connection of RFID-reader
ADM20 and fuel level sensor to the tracker is provided in the Figure 12.
Connection procedure and settings:
1. Set the RFID-reader ADM20 (setting procedure is described in the p. 4.3. of the
Operation Manual “Receiver/transmitter combination ADM20”).
2. Connect RFID-reader ADM20 to the tracker RS-485 bus.
3. Coordinate the work of the tracker and RFID-reader ADM20 (setting procedure is
described in the p. 5 of the Operation Manual “Receiver/transmitter combination ADM20”)