4
EXHAUST SYSTEM
1
2
3
5
5
1. Decide where the ductwork will run between the hood and the outside.
2. A straight, short duct run will allow the hood to perform most efficiently.
3. Long duct runs, elbows and transitions will reduce the performance of
the hood. Use as few of them as possible. Larger ducting may be required
for best performance with longer duct runs.
4. Attach an adequate length 6” (15.2 cm) round duct to the air outlet adapter.
5. The air must not be discharged into a flue that is used for exhausting
fumes from appliances burning gas or other fuels. Regulations
concerning the discharge of air have to be abided by.
6. Install a roof/wall cap. Connect round metal ductwork to cap and work
back towards hood location. Use duct tape to seal the joints between
ductwork sections.
ELECTRICAL CONNECTION
Important: The installation must be done in accordance with all
applicable codes and standards. Refer to a qualified electrician for all
electrical connections.
Turn off electrical power at service entrance before wiring.
If the supply cord is damaged, it must be replaced by a qualified person.
Do not use a plug or an extension cord other than the ones supplied with
the hood. Grounding of this product is compulsory, do not remove the
ground prong from the plug.
ADJUSTABLE CHIMNEY ASSEMBLY (OPTIONAL)
2.1
2.2
1. Raise the decorative chimney top
2.1
inside the decorative chimney
bottom
2.2
.
2. Secure the decorative chimney top
2.1
to the chimney mounting
bracket that is fixed on the wall with the two chimney bracket screws
supplied.
3. Carefully slide the decorative chimney bottom
2.2
down outside the
decorative chimney top
2.1
.
4. Carefully place the decorative chimney bottom
2.2
in the recessed
part of the hood body top.
Chimney mounting
bracket
Round duct (exhaust)
Hood
Note : The arrow
indicates the direction
of the air