background image

 

The plate data is displayed on an adhesive label placed on the outside of the casing, which 
must remain intact and visible.  
The  main information it displays includes: manufacturer's  address,  product name  - model 
number, technical characteristics, production date and serial number. 
In the event of a complaint, please indicate the serial number (SN) displayed on the label.  
An explanation of the symbols used on the label to abbreviate the technical characteristics 
is given in the table in the chapter on “TECHNICAL

 

DATA”. 

6.  Technical data 

Model 

KIMO202 24V

 

Force exerted by traction (F

N

200N 

Force exerted by thrust (F

N

120N (250mm), 150N (170mm)

 

Strokes (S

V

100, 170, 250 mm 

Power supply voltage (U

N

24 V 

 SELV 

Rated absorbed current (I

N

0,45A 

Power absorbed at nominal load (P

N

10,8W 

Electrical insulation 

Class III 

No load speed 

4 mm/s 

Duration of no load stroke 

(250 mm) 

63 s 

Type of service (D

R

5 cycles 

Operating temperature 

- 20 + 70 ºC 

Protection index for electrical devices 

IP42 

Adjustment of connection to window frame  

Automatic definition of position 

Parallel powering of two or more motors 

Yes

 (max 20 actuators)

 

Coupling with K-LOCK electromechanical lock 
and AUX accessories  

Yes 

Synchronised function 

Yes 

(max 8)

 

Nominal holding force 

(it can vary according to 

the chosen brackets)

 

1000N 

Stroke-end at opening 

Electronic by dip-switch setting 

Stroke-end at closing 

At absorption of power 

Length of power cable 

2 m  

Chain exit  

Central 

Dimensions 

21x28,5x354 mm 

Weight 

0,45 Kg 

The data indicated in these figures is not binding and is subject to variation without notification. 

7.  Electric power supply 

The KIMO 202 actuator is powered with a voltage of 24V

 SELV. The power supply cable 

has three conductors: the first conductor 

R

ED

 that should be connected to the + 

(positive)

 

C

LOSES

  the  window;  the  second  conductor 

B

LACK

  that  should  be  connected  to  the  + 

(positive)

 O

PENS

 the window; the third conductor 

G

REEN

 is the conductor used for Syncro³ 

communication, K-LOCK control communication signal and AUX.  
The 24V

 low-voltage actuators can be powered using a unit with emergency batteries or 

a  security  power  supply  unit,

 

at  least  in  Class  2,  with  an  output  voltage  of  24V

 

(min. 

20.4V

,  max.  28,8V

),  that  is  to  say,  sized  based  on  the  number  of  actuators 

connected.  

7.1. 

Selecting the cross-section of the power supply cables 

It is necessary to check the cross-section of the cable, which should be calculated based 
on  the  length  of  the  cable  itself.  The  table  below  specifies  the  maximum  length  of  the 
cables for connection of a motor. 

CABLE SECTION 

Actuator fed at 24V 

 

0.50 mmq 

~40 m 

0.75 mmq 

~60 m 

1.00 mmq 

~80 m 

1.50 mmq 

~120 m 

2.50 mmq 

~200 m 

4.00 mmq 

~320 m 

6.00 mmq 

~480m 

8.  Electrical connection 

The  machines  are  equipped  with  a  power  supply  cable  constructed  in  compliance  with 
safety standards and restrictions on radio-frequency interference.  
The  power  supply  cable  is  made  in  PVC  -  with  conductors  having  a  cross-section  of  0.5 
mm² - and it’s 2 m. long: 

  R

ED

-coloured cable (in the 

drawings marked with “R”) 

  B

LACK

-coloured cable (in the 

drawings marked with “B”) 

  G

REEN

-coloured cable (in the 

drawings marked with “G”)” 

R

G

B

 

For wiring of a single actuator follow the diagram below: 

- +

V

R

N

M

24

V

SCHWARZ

ROT

GRÜN (STEUER-/KOMMUNIKATIONSKABEL)

ROUGE

ROJO

VERT (CÂBLE DE COMMANDE/COMMUNICATION)

VERDE (CABLE DE CONTROL/COMUNICACIÓN)

NEGRO

NOIRE

ROSSO

RED

R

VERDE (CAVO DI CONTROLLO/COMUNICAZIONE)

NERO
BLACK

N

GREEN (CONTROL/COMMUNICATION CABLE)

V

 

Note:

  the  first  conductor 

R

ED

  that  should  be  connected  to  the  +  (positive)  C

LOSES

  the 

window; the second conductor 

B

LACK

 that should be connected to the + (positive) O

PENS

 

the window; the third conductor 

G

REEN

 is the conductor used for the communication signal. 

 

IMPORTANT: when using the actuator in single mode (without any other KIMO202 or 
K-Lock), G

REEN

 wire must be insulated. 

 

Summary of Contents for KIMO 202

Page 1: ...uthorised by the manufacturer Do not use if repair or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION Disconnect the power supply during cleaning or maintenance operations Do not use solvents or jets of water to wash the appliance the appliance should not be submerged in water In th...

Page 2: ...arranty for the appliance In the event of any problems or queries consult your agent or contact the manufacturer directly 4 AREFULLY OBSERVE ALL THE FOLLOWING INSTALLATION INSTRUCTIONS MPROPER INSTALLATION CAN SERIOUSLY ENDANG MANDATORY RISK ANALYSIS AND PROTECTION MEASURES The Nekos electrical actuators comply with the Machinery Directive 2006 42 EC Standard 103 Particular requirements for drives...

Page 3: ... of the window mobile sash only H cm Height of the mobile sash For vertical windows OUTWARD OPENING A BOTTOM HUNG WINDOWS B F 0 54 x P x C H Possible load exerted by snow or wind on the dormer should be calculated separately 3 2 Maximum opening based The selection of the actuator stroke should be made based on the height of the sash and its application As a general rule never select a stroke great...

Page 4: ... the second conductor BLACK that should be connected to the positive OPENS the window the third conductor GREEN is the conductor used for Syncro communication K LOCK control communication signal and AUX The 24V low voltage actuators can be powered using a unit with emergency batteries or a security power supply unit at least in Class 2 with an output voltage of 24V min 20 4V max 28 8V that is to s...

Page 5: ...ctuator should not be installed Check that once the actuator has been installed chain completely in the window If this is not the case the actuator will not function correctly as 9 1 Preparation for mounting the actuator In case of doubts uncertainties or different applications always contact manufacturer For a proper Before beginning to mount the actuator depending on the type of application the ...

Page 6: ...cedure should be carried out with the chain terminal or terminals for configurations with several devices uncoupled from the window sash bracket IMPORTANT The dip switch settings should be changed to non powered actuators after each change it is necessary to wait a few seconds 5 sec before restoring the power to the actuators in order for the change to become effective Set the dip switches in the ...

Page 7: ...eck the electrical contacts at the ends of the actuator cable and ensure that the power supply is correct 9 Chain alignment error The misalignment of the chain Repeat the RESET procedure 14 terminal positions on devices connected in a Syncro configuration exceeds the maximum amount allowed 10 Memory error The internal memory write process failed Repeat the RESET procedure 11 Connection error A RES...

Page 8: ...rtake to replace defective parts due to poor quality materials or manufacturing defects in accordance with article 1490 of the Civil Code The guarantee covers products and from the date of purchase The latter is valid as long as the purchaser possesses proof of purchase and completion of all agreed conditions of Guarantee of good function of appliances agreed by the manufacturer implies that the l...

Reviews: