7
The plate data is displayed on an adhesive label placed on the outside of the casing, which
must remain intact and visible.
The main information it displays includes: manufacturer's address, product name - model
number, technical characteristics, production date and serial number.
In the event of a complaint, please indicate the serial number (SN) displayed on the label.
An explanation of the symbols used on the label to abbreviate the technical characteristics
is given in the table in the chapter on “TECHNICAL
DATA”.
6. Technical data
Model
KIMO202 24V
Force exerted by traction (F
N
)
200N
Force exerted by thrust (F
N
)
120N (250mm), 150N (170mm)
Strokes (S
V
)
100, 170, 250 mm
Power supply voltage (U
N
)
24 V
SELV
Rated absorbed current (I
N
)
0,45A
Power absorbed at nominal load (P
N
)
10,8W
Electrical insulation
Class III
No load speed
4 mm/s
Duration of no load stroke
(250 mm)
63 s
Type of service (D
R
)
5 cycles
Operating temperature
- 20 + 70 ºC
Protection index for electrical devices
IP42
Adjustment of connection to window frame
Automatic definition of position
Parallel powering of two or more motors
Yes
(max 20 actuators)
Coupling with K-LOCK electromechanical lock
and AUX accessories
Yes
Synchronised function
Yes
(max 8)
Nominal holding force
(it can vary according to
the chosen brackets)
1000N
Stroke-end at opening
Electronic by dip-switch setting
Stroke-end at closing
At absorption of power
Length of power cable
2 m
Chain exit
Central
Dimensions
21x28,5x354 mm
Weight
0,45 Kg
The data indicated in these figures is not binding and is subject to variation without notification.
7. Electric power supply
The KIMO 202 actuator is powered with a voltage of 24V
SELV. The power supply cable
has three conductors: the first conductor
R
ED
that should be connected to the +
(positive)
C
LOSES
the window; the second conductor
B
LACK
that should be connected to the +
(positive)
O
PENS
the window; the third conductor
G
REEN
is the conductor used for Syncro³
communication, K-LOCK control communication signal and AUX.
The 24V
low-voltage actuators can be powered using a unit with emergency batteries or
a security power supply unit,
at least in Class 2, with an output voltage of 24V
(min.
20.4V
, max. 28,8V
), that is to say, sized based on the number of actuators
connected.
8
7.1.
Selecting the cross-section of the power supply cables
It is necessary to check the cross-section of the cable, which should be calculated based
on the length of the cable itself. The table below specifies the maximum length of the
cables for connection of a motor.
CABLE SECTION
Actuator fed at 24V
0.50 mmq
~40 m
0.75 mmq
~60 m
1.00 mmq
~80 m
1.50 mmq
~120 m
2.50 mmq
~200 m
4.00 mmq
~320 m
6.00 mmq
~480m
8. Electrical connection
The machines are equipped with a power supply cable constructed in compliance with
safety standards and restrictions on radio-frequency interference.
The power supply cable is made in PVC - with conductors having a cross-section of 0.5
mm² - and it’s 2 m. long:
R
ED
-coloured cable (in the
drawings marked with “R”)
B
LACK
-coloured cable (in the
drawings marked with “B”)
G
REEN
-coloured cable (in the
drawings marked with “G”)”
R
G
B
For wiring of a single actuator follow the diagram below:
- +
V
R
N
M
24
V
SCHWARZ
ROT
GRÜN (STEUER-/KOMMUNIKATIONSKABEL)
ROUGE
ROJO
VERT (CÂBLE DE COMMANDE/COMMUNICATION)
VERDE (CABLE DE CONTROL/COMUNICACIÓN)
NEGRO
NOIRE
ROSSO
RED
R
VERDE (CAVO DI CONTROLLO/COMUNICAZIONE)
NERO
BLACK
N
GREEN (CONTROL/COMMUNICATION CABLE)
V
Note:
the first conductor
R
ED
that should be connected to the + (positive) C
LOSES
the
window; the second conductor
B
LACK
that should be connected to the + (positive) O
PENS
the window; the third conductor
G
REEN
is the conductor used for the communication signal.
IMPORTANT: when using the actuator in single mode (without any other KIMO202 or
K-Lock), G
REEN
wire must be insulated.