USER INSTRUCTIONS 

 

 
 

CAUTION:  Carefully  observe  all  the  following  installation 
instructions to ensure personal safety.  
The  device  is  not  intended  for  use  by  persons  (including 
children) with  reduced  physical, sensory or mental capabilities, 
or  lacking  experience  and  knowledge.  Do  not  allow  children  to 
play  with  the  fixed  controls  and  keep  any  remote-control  units 
out of their reach. 
Have  installation  checks  performed  periodically  by  qualified 
personnel from a service centre authorised by the manufacturer. 
Do not use if repair or adjustment is required.  
CAUTION: if the power cable is damaged, it must be replaced by 
qualified  personnel  from  a  service  centre  authorised  by  the 
manufacturer. 
CAUTION.  Disconnect  the  power  supply  during  cleaning  or 
maintenance operations. Do not use solvents or jets of water to 
wash  the  appliance;  the  appliance  should  not  be  submerged  in 
water. 
In the event of fault or malfunction, switch off the device at the 
main switch. All repairs and adjustments (e.g. setting the stroke) 
must  only  be  performed  by  qualified  personnel  from  a  service 
centre authorised by the manufacturer.  
Always request exclusive use of  original spare parts. Failure to 
respect  this  condition  could  compromise  safety  and  invalidate 
the  benefits  contained  in  the  warranty  for  the  appliance.  In  the 
event of any problems or queries, consult your agent or contact 
the manufacturer directly. 
The A-weighted sound pressure level is less than 70dB(A). 
Carefully preserve these instructions after installation. 

 
 
 
 
 

Summary of Contents for KIMO 202

Page 1: ...uthorised by the manufacturer Do not use if repair or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION Disconnect the power supply during cleaning or maintenance operations Do not use solvents or jets of water to wash the appliance the appliance should not be submerged in water In th...

Page 2: ...arranty for the appliance In the event of any problems or queries consult your agent or contact the manufacturer directly 4 AREFULLY OBSERVE ALL THE FOLLOWING INSTALLATION INSTRUCTIONS MPROPER INSTALLATION CAN SERIOUSLY ENDANG MANDATORY RISK ANALYSIS AND PROTECTION MEASURES The Nekos electrical actuators comply with the Machinery Directive 2006 42 EC Standard 103 Particular requirements for drives...

Page 3: ... of the window mobile sash only H cm Height of the mobile sash For vertical windows OUTWARD OPENING A BOTTOM HUNG WINDOWS B F 0 54 x P x C H Possible load exerted by snow or wind on the dormer should be calculated separately 3 2 Maximum opening based The selection of the actuator stroke should be made based on the height of the sash and its application As a general rule never select a stroke great...

Page 4: ... the second conductor BLACK that should be connected to the positive OPENS the window the third conductor GREEN is the conductor used for Syncro communication K LOCK control communication signal and AUX The 24V low voltage actuators can be powered using a unit with emergency batteries or a security power supply unit at least in Class 2 with an output voltage of 24V min 20 4V max 28 8V that is to s...

Page 5: ...ctuator should not be installed Check that once the actuator has been installed chain completely in the window If this is not the case the actuator will not function correctly as 9 1 Preparation for mounting the actuator In case of doubts uncertainties or different applications always contact manufacturer For a proper Before beginning to mount the actuator depending on the type of application the ...

Page 6: ...cedure should be carried out with the chain terminal or terminals for configurations with several devices uncoupled from the window sash bracket IMPORTANT The dip switch settings should be changed to non powered actuators after each change it is necessary to wait a few seconds 5 sec before restoring the power to the actuators in order for the change to become effective Set the dip switches in the ...

Page 7: ...eck the electrical contacts at the ends of the actuator cable and ensure that the power supply is correct 9 Chain alignment error The misalignment of the chain Repeat the RESET procedure 14 terminal positions on devices connected in a Syncro configuration exceeds the maximum amount allowed 10 Memory error The internal memory write process failed Repeat the RESET procedure 11 Connection error A RES...

Page 8: ...rtake to replace defective parts due to poor quality materials or manufacturing defects in accordance with article 1490 of the Civil Code The guarantee covers products and from the date of purchase The latter is valid as long as the purchaser possesses proof of purchase and completion of all agreed conditions of Guarantee of good function of appliances agreed by the manufacturer implies that the l...

Reviews: