background image

2. FORMULAS AND RECOMMENDATIONS FOR INSTALLATION  

2.1.  Calculation of opening / closure force 

Using the formulas below, approximate calculations can be made for the force required 
to open or close the window considering all the factors that determine the calculation.  

Symbols used for the calculation  

F (Kg) = Force for opening or closing 

P (Kg) = Weight of the window

 (mobile sash only)

 

C (cm) = Opening stroke (actuator stroke) 

H (cm) = Height of the mobile sash 

 

For horizontal light domes or 

skylights 

 

F = 0.54 x P 

(Eventual  weight of  snow or  wind on the 
cupola should be calculated separately)

.

 

For vertical windows 

 

TOP HUNG WINDOWS

,

 OUTWARD OPENING

 (A) 

 

BOTTOM HUNG WINDOWS

 (B) 

F = 0.54 x P x C : H 

(Eventual  load  of  favourable  or  unfavourable 
wind  on  the  sash  should  be  calculated 
separately.)

 

2.2.  Maximum opening according to height of sash 

The  actuator  stroke  is  in  accordance  with  the  height  of  the  sash  and  its  application. 
Check that the actuator stroke does not touch the profile of the sash and that the chain 
does not exert force on the window frame (measurements in mm).  

A

TTENTION

.

  For  safety  reasons  the  actuator  should  not  be  assembled  if  dimensions  are 

inferior to those indicated in the table below. In the event that the height of the sash should 
be lower, call on the manufacturer to check the appliance. 

Mode of installation 

Selection of actuator stroke 

110 

200 

300 

400 

Light domes, skylights or vertical top hung windows 
opening outwards with frontal assembly 

150 

250 

350 

450 

Top hung windows opening outwards with 
horizontal assembly 

150 

250 

350 

450 

Bottom hung windows 

(motor on frame)

 

250 

450 

600 

700 

Bottom hung windows 

(motor on sash)

 

Consult manufacturer 

3. TECHNICAL INFORMATION ABOUT FUNCTION 

The  chain  operated  actuator  opens  and  closes  windows  by  means  of  a  steel  chain 
located  inside  the  cover.  Movement  is  powered  by  electricity  which  powers  a  gear 
motor controlled by an electronic function device. Window opening can be programmed 
to open at 110, 200, 300 and 400 mm 

(see respective chapter)

During  closure  the  end  course  uses  a  self-regulating  electronic  process  with  power 
absorption and therefore requires no regulation. 
The  actuator  leaves  the  factory  with  factory  settings  of  +1  cm  for  the  return  course 
which allows the actuator to be assembled without electricity, with the window in closed 
position after assembly is complete.  

4. MANUFACTURE AND REFERENCE STANDARDS 

 

INTENDED USE.

 The KATO ADV RADIO chain actuator is designed and built 

to open and close awning and bottom-hung windows, dormer windows, domes 
and skylights used for ventilation and climate control in rooms; any other use is 
strongly  discouraged,  with  the  supplier  of  the  entire  system  in  any  case 
retaining  sole  liability.  It  can  also  be  used  in  combination  with  the 

NRS1

 

operated rain sensors. 
The  actuator  is  manufactured  in  accordance  with  the  Directives  and  following 
Regulations  listed  in  the  attached  Declaration  of  Incorporation  and  Conformity 

Electrical connections  must  conform  to  regulations  in  force  for  the  design  and 
set up of electrical equipment. 
To  ensure  efficient  separation  from  the  grid,  an  approved  type  of  bipolar  “dead-
man”  switch  should  be  used.  An  omnipolar  general  power  switch  with  minimum 
distance  of  3  mm  between  contacts  should  be  installed  upstream  of  the  control 
line. 

The KATO ADV RADIO actuator is packed in one single carton. 
Each package contains: 

  Actuator with 2 metre (±5%) lead. 

  Standard support brackets with distancer (A). 

  Bracket for vertical assembly of the actuator (B). 

  Bracket for transom window (C). 

  Bracket for outward opening fixture (D). 

  Template for boring. 

  Instruction manual. 

5. LABEL DATA AND MARKINGS 

The  KATO  ADV  RADIO  actuators  have  CE  marking  and  comply  with  the  Standards 
listed  in  the  Declaration  of  Conformity.  They  also  come  with  a  Declaration  of 
Incorporation, due to their classification by the Machinery Directive as “partly completed 
machines”. Both declarations are included in the final pages of this manual. 

Summary of Contents for KATO ADV RADIO

Page 1: ...air or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION Disconnect the power supply...

Page 2: ...he supplier of the complete system retains full liability For systems installed at a height of less than 2 5 m above floor level or other levels accessible to users the manufacturer supplier of the wi...

Page 3: ...lled by an electronic function device Window opening can be programmed to open at 110 200 300 and 400 mm see respective chapter During closure the end course uses a self regulating electronic process...

Page 4: ...alternating current of 110 230V with a frequency of 50 60 Hz The actuator is already equipped with a power supply cable which is 2 meters long The cable has two colored conductors Phase brown and Neut...

Page 5: ...es of quick flashes for about 1 second then the LED will go out and remain at rest 10 10 1 2 Erasing the radio memory To completely erase the memory of the radio remote control on the machine press th...

Page 6: ...the electrical protection mechanism the chain moves in the opposite direction for around 1 0 1 5 mm This is to loosen the tension of the mechanical parts and gives correct pressure to the weather stri...

Page 7: ...bly on transom window Aside the drawing of specific application using accessories provided For different mountings please contact manufacturer Before starting check that there are at least two mechani...

Page 8: ...cases it flashes in different ways depending on the signal it is emitting the different flashing modes indicate the precise behavior of the actuator during the programming of the machine radio remote...

Page 9: ...ing as established from laws in force on recycling The device is mainly made from the following materials aluminium zinc iron plastic of various type cuprum Dispose materials in conformity with local...

Page 10: ...irettiva sulla restrizione dell uso di determinate sostanze pericolose nelle apparecchiature elettriche ed elettroniche Direttiva RoHS Restriction of the use of certain hazardous substances Directive...