background image

13 

14.2.   Assembly with outward opening window 

Aside  the  drawing  of  specific  application  using 
accessories  provided.  For  different  mountings, 
please contact manufacturer. 

A. 

Pencil  in  an  “X”  over  the  centre  line  of  the  window 
frame (

Fig. 2

). 

B. 

Select the correct form of brackets (

Fig. 3

). 

C. 

Attach  the  template  to  the  window  frame 

(fixed  part)

 

and  line  axis  up  with  the  centre  line  “X” traced  earlier 

(Fig. 4)

Warning

: for window frames not on the same 

plane, cut the part of the template coloured in grey and 
fix  this  to  the  moveable  part  of  the  window  frame, 
taking care to keep it in the same position. 

D. 

Bore holes in the window frame at the points indicated 
on the template 

(Fig. 5)

E. 

Assemble the two  brackets with the distancer 

(to help 

position correctly. Once it has served its purpose it can 
be  removed)

.  Mount  the  supports  onto  the  frame  with 

the  appropriate  screws  provided.  Check  that 
everything is aligned both horizontally and vertically. 

F. 

Mount  the  bracket  for  outward  opening  windows  onto 
the moveable part of the frame in accordance with the 
markings indicated on the template. 

G. 

Complete  assembly  of  the  chain  terminal  with  the 
safety  clip  inserted  onto  the  pin  Ø4x32 

(provided)

  in 

median position 

(see fig. 6)

H. 

Mount  the  actuator  onto  the  brackets  by  inserting  the 
two openings at each side onto the corresponding pins 
on the brackets. 

I. 

Rotate the actuator 90°, bring the chain terminal up to 
the  bracket and insert  the  pin into the opening  on the 
bracket. Insert the safety clip into the bracket. 

J. 

Check  that  the  exit  on  the  chain  is  perfectly  aligned 
with  the  bracket.  If  the  chain  is  not  aligned  with  the 
bracket,  loosen  the  fixing  screws  and  reposition  the 
bracket correctly. 

K. 

Check  all  electrical  connections  with  the  diagram  on 
the label attached to the lead and and in conformity to 
indications on chapter 9 – Electrical connection.  

L. 

Carry out a complete check of opening and closure of 
the  window.  Once  the  closure  phase  has  been 
completed, check that the window frame is completely 
closed by checking the pressure on the weather strips.

 

 

Outward application 

 

Figure 2 

 

Figure 3 

 

Figure 4 

 

Figure 5 

 

Figure 6 

14 

14.3.  Assembly on transom window 

Aside  the  drawing  of  specific  application  using 
accessories provided. For different mountings, please 
contact manufacturer. 

Before  starting,  check  that  there  are  at  least  two 
mechanical compass safety stops or other form of 
stops connected to the frame, and ensure that the 

stops can prevent any accidental fall of the window. Your 
safety is at hand. 

A. 

Pencil  in  an  “X”  over  the  centre  line  of  the  window 
frame (Fig. 7).  

B. 

Select the correct form of brackets (Fig. 8). 

C. 

Attach  the  template  to  the  window  frame  (fixed  part) 
and  line  axis  up  with  the  centre  line  “X” traced  earlier 
(Fig. 9). Warning: for window frames not on the same 
plane, cut the part of the template coloured in grey and 
fix  this  to  the  moveable  part  of  the  window  frame, 
taking care to keep it in the same position. 

D. 

Bore holes in the window frame at the points indicated 
on the template (Fig. 10). 

E. 

Assemble the two  brackets with the distancer (to help 
position correctly. Once it has served its purpose it can 
be  removed).  Mount  the  supports  onto  the  frame  with 
the  appropriate  screws  provided.  Check  that 
everything is aligned both horizontally and vertically. 

F. 

Mount  the  bracket  for  outward  opening  windows  onto 
the moveable part of the frame in accordance with the 
markings indicated on the template. 

G. 

Complete  assembly  of  the  chain  terminal  with  the 
safety  clip  inserted  onto  the  provided  pin  Ø4x32  in 
median position (see fig. 11). 

H. 

Mount  the  actuator  onto  the  brackets  by  inserting  the 
two openings at each side onto the corresponding pins 
on the brackets. 

I. 

Rotate the actuator 90°, bring the chain terminal up to 
the  bracket and insert  the  pin into the opening  on the 
bracket. Insert the safety clip into the bracket. 

J. 

Check  that  the  exit  on  the  chain  is  perfectly  aligned 
with  the  bracket.  If  the  chain  is  not  aligned  with  the 
bracket,  loosen  the  fixing  screws  and  reposition  the 
bracket correctly. 

K. 

Check  all  electrical  connections  with  the  diagram  on 
the  label  attached  to  the  lead  and  in  conformity  to 
indications on chapter 9 – Electrical connection.  

L. 

Carry out a complete check of opening and closure of 
the  window.  Once  the  closure  phase  has  been 
completed, check that the window frame is completely 
closed by checking the pressure on the weather strips.

 

 

Inward application–transom window 

 

Figure 7 

 

Figure 8 

 

Figure 9 

 

Figure 10 

 

Figure 11 

Summary of Contents for KATO ADV RADIO

Page 1: ...air or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION Disconnect the power supply...

Page 2: ...he supplier of the complete system retains full liability For systems installed at a height of less than 2 5 m above floor level or other levels accessible to users the manufacturer supplier of the wi...

Page 3: ...lled by an electronic function device Window opening can be programmed to open at 110 200 300 and 400 mm see respective chapter During closure the end course uses a self regulating electronic process...

Page 4: ...alternating current of 110 230V with a frequency of 50 60 Hz The actuator is already equipped with a power supply cable which is 2 meters long The cable has two colored conductors Phase brown and Neut...

Page 5: ...es of quick flashes for about 1 second then the LED will go out and remain at rest 10 10 1 2 Erasing the radio memory To completely erase the memory of the radio remote control on the machine press th...

Page 6: ...the electrical protection mechanism the chain moves in the opposite direction for around 1 0 1 5 mm This is to loosen the tension of the mechanical parts and gives correct pressure to the weather stri...

Page 7: ...bly on transom window Aside the drawing of specific application using accessories provided For different mountings please contact manufacturer Before starting check that there are at least two mechani...

Page 8: ...cases it flashes in different ways depending on the signal it is emitting the different flashing modes indicate the precise behavior of the actuator during the programming of the machine radio remote...

Page 9: ...ing as established from laws in force on recycling The device is mainly made from the following materials aluminium zinc iron plastic of various type cuprum Dispose materials in conformity with local...

Page 10: ...irettiva sulla restrizione dell uso di determinate sostanze pericolose nelle apparecchiature elettriche ed elettroniche Direttiva RoHS Restriction of the use of certain hazardous substances Directive...

Reviews: