13
14.2. Assembly with outward opening window
Aside the drawing of specific application using
accessories provided. For different mountings,
please contact manufacturer.
A.
Pencil in an “X” over the centre line of the window
frame (
Fig. 2
).
B.
Select the correct form of brackets (
Fig. 3
).
C.
Attach the template to the window frame
(fixed part)
and line axis up with the centre line “X” traced earlier
(Fig. 4)
.
Warning
: for window frames not on the same
plane, cut the part of the template coloured in grey and
fix this to the moveable part of the window frame,
taking care to keep it in the same position.
D.
Bore holes in the window frame at the points indicated
on the template
(Fig. 5)
.
E.
Assemble the two brackets with the distancer
(to help
position correctly. Once it has served its purpose it can
be removed)
. Mount the supports onto the frame with
the appropriate screws provided. Check that
everything is aligned both horizontally and vertically.
F.
Mount the bracket for outward opening windows onto
the moveable part of the frame in accordance with the
markings indicated on the template.
G.
Complete assembly of the chain terminal with the
safety clip inserted onto the pin Ø4x32
(provided)
in
median position
(see fig. 6)
.
H.
Mount the actuator onto the brackets by inserting the
two openings at each side onto the corresponding pins
on the brackets.
I.
Rotate the actuator 90°, bring the chain terminal up to
the bracket and insert the pin into the opening on the
bracket. Insert the safety clip into the bracket.
J.
Check that the exit on the chain is perfectly aligned
with the bracket. If the chain is not aligned with the
bracket, loosen the fixing screws and reposition the
bracket correctly.
K.
Check all electrical connections with the diagram on
the label attached to the lead and and in conformity to
indications on chapter 9 – Electrical connection.
L.
Carry out a complete check of opening and closure of
the window. Once the closure phase has been
completed, check that the window frame is completely
closed by checking the pressure on the weather strips.
Outward application
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
14
14.3. Assembly on transom window
Aside the drawing of specific application using
accessories provided. For different mountings, please
contact manufacturer.
Before starting, check that there are at least two
mechanical compass safety stops or other form of
stops connected to the frame, and ensure that the
stops can prevent any accidental fall of the window. Your
safety is at hand.
A.
Pencil in an “X” over the centre line of the window
frame (Fig. 7).
B.
Select the correct form of brackets (Fig. 8).
C.
Attach the template to the window frame (fixed part)
and line axis up with the centre line “X” traced earlier
(Fig. 9). Warning: for window frames not on the same
plane, cut the part of the template coloured in grey and
fix this to the moveable part of the window frame,
taking care to keep it in the same position.
D.
Bore holes in the window frame at the points indicated
on the template (Fig. 10).
E.
Assemble the two brackets with the distancer (to help
position correctly. Once it has served its purpose it can
be removed). Mount the supports onto the frame with
the appropriate screws provided. Check that
everything is aligned both horizontally and vertically.
F.
Mount the bracket for outward opening windows onto
the moveable part of the frame in accordance with the
markings indicated on the template.
G.
Complete assembly of the chain terminal with the
safety clip inserted onto the provided pin Ø4x32 in
median position (see fig. 11).
H.
Mount the actuator onto the brackets by inserting the
two openings at each side onto the corresponding pins
on the brackets.
I.
Rotate the actuator 90°, bring the chain terminal up to
the bracket and insert the pin into the opening on the
bracket. Insert the safety clip into the bracket.
J.
Check that the exit on the chain is perfectly aligned
with the bracket. If the chain is not aligned with the
bracket, loosen the fixing screws and reposition the
bracket correctly.
K.
Check all electrical connections with the diagram on
the label attached to the lead and in conformity to
indications on chapter 9 – Electrical connection.
L.
Carry out a complete check of opening and closure of
the window. Once the closure phase has been
completed, check that the window frame is completely
closed by checking the pressure on the weather strips.
Inward application–transom window
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11