background image

 

 

Page 7 

  Electrical  connections  must  comply  with  standards  in  force  on  the  design  and 

production of electrical appliances.  

  The actuator has been manufactured according to European Union directives and 

conforms to 

 marking. 

  Any eventual service or control device for the actuator must be produced according to 

standards  in  force  and  must  comply  with  the  standards  issued  by  the  European 
Community.  

The actuator is packaged in cardboard boxing and each package contains: 

  Electrical  actuator  with  either  110÷230V~  (a.c.) 

50/60Hz  or  24V═  (d.c.)  with 

electrical cable directly connected to the machine. 

  Drilling template. 

  Standard support brackets (A). 

  Bracket for bottom hung window (C). 

  Bracket for top hung window (D). 

  Instructions manual. 

5. Technical data 

Model 

KATO 253/230V 

KATO 253/24V 

Force exerted by thrust and traction 

250 N 

Strokes 

(can be selected at any time)

 

240, 360 mm 

Power supply voltage 

110÷230V~ (a.c.) 

50/60Hz 

24V

═ (d.c.) 

Rated absorbed current 

0,180 A 

0,800  A 

Power absorbed at nominal load 

~ 30 W 

~ 18 W 

No load speed 

13,5 mm/s 

12,8 mm/s 

Duration of no load stroke 

(240-360 mm) 

18 s 

– 27 s 

19 s 

– 28 s 

Double electrical insulation 

YES 

Type of service 

S

2

 of 3 min 

Operating temperature 

- 5  + 65 ºC 

Protection index for electrical devices 

IP30 

Adjustment of connection to window frame  

Automatic definition of position 

Parallel powering of two or more motors 

YES 

(max 30 actuators)

 

Synchronised function 

Not foreseen 

Static hold force 

1500N 

Stroke-end at opening 

At absorption of power 

Stroke-end at closing 

At absorption of power 

Length of power cable 

1 m 

Dimensions 

356x56x33,5 mm 

Weight 

0,840 Kg 

0,820 Kg 

The data indicated in these figures is not binding and is subject to variation without notification. 

 

 

Summary of Contents for KATO 253

Page 1: ...Code 4420052 Edition no 3 of October 2012 K KA AT TO O 2 25 53 3 CHAIN OPERATED ACTUATOR FORCE 250 N MAXIMUM STROKE 360 MM VOLTAGE 110 230V A C 50 60HZ 24V D C MANUAL FOR INSTALLATION AND USE English...

Page 2: ...ing and indications for use provided with the product indicate presumed conformity to the directives issued by the European Community The manufacturer holds the technical archive with documentation pr...

Page 3: ...trical power supply 8 7 1 Selection of power cable section 8 8 Instructions for assembly 9 8 1 Preparation of actuator for assembly 9 8 2 Assembly for top hung windows outward opening 10 8 3 Assembly...

Page 4: ...is destined exclusively for the use for which it has been designed and the manufacturer accepts no responsibility for damage incurred by improper use The actuator is destined exclusively for installat...

Page 5: ...ion switch the appliance off at the general switch and call for the services of a qualified technician 2 Formulas and recommendations for installation 2 1 Calculation of opening closure force Using th...

Page 6: ...nerated using electrical energy that powers a reduction motor controlled by a functional electrical device Windows can be programmed to open and the device allows chain opening at 240 and 360 mm When...

Page 7: ...KATO 253 230V KATO 253 24V Force exerted by thrust and traction 250 N Strokes can be selected at any time 240 360 mm Power supply voltage 110 230V a c 50 60Hz 24V d c Rated absorbed current 0 180 A 0...

Page 8: ...KATO 253 actuator is commercially available in two versions identified according to electrical specifications 1 KATO 253 230V a c runs on grid tension of 110 230V a c 50 60Hz 10 with a three wire cabl...

Page 9: ...he window where the actuator is to be assembled is over 375 mm otherwise the actuator should not be installed Check that once the actuator has been installed the distance between the fixed part of the...

Page 10: ...template Fig 5 E Apply the brackets A to the window frame using flat head screws as indicated above Check both horizontal and vertical alignment of brackets F Assemble the hinge for top hung windows...

Page 11: ...emplate coincides with centrepoint X traced earlier Fig 9 Attention for non coplanar window frames cut the grey part of the template along the green line and apply onto the mobile part of the window f...

Page 12: ...t the seals 9 Electrical connections Machines have been equipped with a power connection cable which complies with safety regulations and protection against radio disturbance Before performing the ele...

Page 13: ...rect compression to the seals and release the mechanical parts Check that hinges and support brackets are rigidly attached to the window frame and all screws correctly fixed into position For aluminiu...

Page 14: ...tion during installation or use Problem Possible cause Solution Actuator does not work No electricity at feeder Check status of circuit breaker or safety switch Cable not connected or wire disconnecte...

Page 15: ...6 Certificato di conformita DECLARATION OF CONFORMITY NEKOS S r l Via Capitoni 7 5 36064 Mason Vicentino VI ITALY 0424 411011 Fax 0424 411013 www nekos it info nekos it Il sottoscritto legale rapprese...

Page 16: ...Page 16 NEKOS S r l I 36064 MASON VICENTINO VI Via Capitoni 7 5 Telephone 0039 0424 411011 Fax 0039 0424 411013 info nekos it http www nekos it...

Reviews: