6. TOOL USE
Before each use of the tool, make sure that no parts of the air system are
damaged. If you notice damage, immediately replace the components with new,
undamaged ones. Dry condensed moisture inside the tool, compressor and hose
before each use of the air system.
Preparing the tool for operation
Screw a suitable nozzle to the air inlet thread firmly and securely to connect the
air supply hose.Install the additional handle to the housing using screws.Before
installing the blade, make sure that the permissible rotation speed of the blade is
equal to or higher than that of the grinder. Holding the spindle with one wrench,
remove the blade fixing screw firmly and securely using the other wrench.Mount
the blade with the dimensions specified in the technical data table on the
spindle.Place the ring under the screw and screw it in. Holding the spindle with
one wrench, tighten the blade fixing screw firmly and securely using the other
wrench.Manually rotate the blade (several revolutions) to ensure that the blade
rotates smoothly and without jams. The tool is ready to be connected to a
pneumatic system.
Starting and stopping the tool
Caution! Before starting the pneumatic tool, make sure that the mounted inserted
tool does not come into contact with any object or any body part. The tool is
operated by means of a lever which opens the air valve and thus ensures the
supply of compressed air to the tool drive. If the lever is equipped with a lock that
prevents the lever from being accidentally pressed. Turn the lock, so that it is
parallel to the lever, and then pull the lever towards the tool housing. This will
start the tool. Allow the tool to reach its rated speed and only then start working.
Working with the cutter
Do not use the cutting blade for side grinding. Allow the blade to run at full speed
before starting to cut. Apply only the rotating blade to the material. When cutting,
apply only the same pressure to the tool as is required for cutting the workpiece
Excessive pressure can damage the cutting blade, which increases the risk of
injury.Securely clamp the workpiece to prevent accidental movement during