5
diabetes, or Raynaud s Disease should not use this tool. If you feel any symptoms related
to vibration (such as tingling, numbness, and white or blue fingers), seek medical advice
as soon as possible.
2. Do not smoke during use. Nicotine reduces the blood supply to the hands and fingers,
increasing the risk of vibration-related injury.
3. Wear suitable gloves to reduce the vibration effects on the user.
4. Use tools with the lowers vibration when there is a choice.
5. Include vibration-free periods each day of work.
6. Grip the tool as lightly as possible (while still maintaining a secure hold). Let the tool do
the work.
7. To reduce vibration, maintain tool as explained in this manual. If abnormal vibration
occurs, stop immediately.
SPECIFICATIONS
Max. speed:16000/min
Avg. air consumption:4cfm
Max. operating pressure:6.2bar(90Psi)
Air inlet:1/4"
INITIAL SETUP & ASSEMBLY
Air Supply
WARNING: To prevent serious injury from explosion, use only clean, dry, regulated,
compressed air to power this tool. Do not use oxygen, carbon dioxide, combustible gases,
or any other bottled gas as a power source for this tool.
1. Incorporate a filter, regulator with pressure gauge, oiler, in-line shutoff valve, and quick
coupler for best service. Refer to the diagram at the end of this manual for more
information. An in-line shut-off ball valve is an important safety device because it controls the
air supply even if the air hose is ruptured. The shut-off valve should be
a ball valve because it can be closed quickly.
Note: if an automatic oiler system is not used, add a few drops of pneumatic tool oil to the
airline connection before operation. Add a few more drops after each hour of continual use.
2. Attach an air hose to the compressor s air outlet. Connect the air hose to the air inlet of
the tool. Other components, such as a coupler plug and quick coupler, will make
operation more efficient, but are not required.
WARNING: To prevent serious injury from accidental operation, do not install a female
quick coupler on the tool. Such a coupler contains an air valve that will allow the air tool to
retain pressure and operate accidentally after the air supply is disconnected.
Note: Air flow, and therefore tool performance, can be hindered by undersized air supply
components. The air hose must be long enough to reach the work area with enough extra
length to allow free movement while working.
3. Release the tool s trigger.