background image

6

Appliance version

Recirculating air

operation with

activated carbon

filter

Speed

E x h a u s t   a i r o p e r a t i o n

120 mm dia.

DIN

free-

blowing

150 mm dia.

DIN

free-

blowing

2 fan speeds
single motor

3 fan speeds
single motor

3 fan speeds
dual motor

slide control
single motor

slide control
dual motor

min.

max.

min.

max.

min.

max.

min.

max.

Normal speed
min.
max.

full speed

160
250

140
280

170
360

170
300

200

380

500

170
265

160
290

180
380

180
320

220

400

540

120
170

130
230

120
280

180
320

230

410

540

130
200

140
260

140
330

185
330

230

420

560

140
210

120
230

140
300

140
260

140

290

360

Ventilation capacity

in m

3

/h according to DIN 44971 and freeblowing

Technical data

Mounting wall covering rail:

The gap between the hood and the rear
wall can be dressed with the enclosed
covering rail. Fig. 18.
Screw-fasten the covering rail to the
underside of the extractor hood. Fig. 18.

Refit the grease filter 

(see instruction

manual).

If the unit door has to be removed:

Pull the red plastic catches in the 
housing on both sides inwards to 
release the door, which can then be 
pulled out towards you. Fig. 14.

We reserve the right to construction changes within the
context of technical development.

Installation

Weight in kg

Exhaust air

6,5

8,0

Recirculating

air

7,8

9,3

Appliance version

single motor

dual motor

5750.175 652-en  16.11.2006  9:35 Uhr  Seite 6

Summary of Contents for D 26 Series

Page 1: ...Installation instructions for the built in cooker hood D 26 NEFF GB Ltd ...

Page 2: ...fore reading this manual please unfold the illustrations at the back Old appliances still have some resi dual value An environment friendly method of disposal will ensure that valuable raw materials can be recovered and used again Before you dispose of your old applian ce make sure that it has been rendered inoperable Your new appliance was protected by suitable packaging while it was on its way t...

Page 3: ...operation of coo king appliances such as hobs and gas cookers Exhaust air routing must always comply with local authority regulations If the extraction hood is used in recircu lating operation with activated carbon filter unrestricted operation is possible With exhaust mode a backwash valve should be installed unless it is already incorporated in the exhaust pipe or wall box Fig 3 If a backwash va...

Page 4: ...tor comes as standard equip ped with a protective grid in the air connec tor If this is has been removed in the case of exhaust air operation the air connector must be supplemented by a reducer piece with protective grid see section on special accessories in the instruction manual Electrical connection WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT Fitting a Different Plug The wires in the mains...

Page 5: ...tightened Fig 12 7 Connect pipes 8 Connect electricity Mounting the door Door thickness min 16 mm Door height 380 to 700 mm Door weight max 7 kg In order to match the wall cabinets on either side the door can project at the top and bottom Fig 13 1 Remove the two door carriers to the right and left by pulling both the red plastic catches inwards and removing the door carrier out towards you Fig 14 ...

Page 6: ...40 210 120 230 140 300 140 260 140 290 360 Ventilation capacity in m3 h according to DIN 44971 and freeblowing Technical data Mounting wall covering rail The gap between the hood and the rear wall can be dressed with the enclosed covering rail Fig 18 Screw fasten the covering rail to the underside of the extractor hood Fig 18 Refit the grease filter see instruction manual If the unit door has to b...

Page 7: ...5750 175652 Printed in Germany 1106 Hi NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399 ...

Reviews: