Important

Installation of the

extractor hood 

at

a minimum distance of

650 mm (

Fig. 1)

is only permissible above a gas hob if
the following rated heat loads (Hs) are
not exceeded:

Gas cookers

load on one burner               max. 

0

3.0 kW

load on all burners                max. 

0

8.3 kW

load on oven                         max. 

0

3.9 kW

Gas hobs

load on one burner               max. 

0

3.9 kW

load on all burners                max. 11.3 kW

Gas glass-ceramic hotplate

The data on nominal heat loads do
not apply to gas glass-ceramic hot-
plates. Be sure to observe the
instructions provided by the manu-
facturer of the hotplate.

Solid-fuel cookers

The maximum nominal heat loads
and the minimum distance are the
same as for gas cookers.

Installation of the extractor hood is

only permissible over a solid fuel stove
(which may constitute a fire hazard, e.g.
from sparks), provided the solid-fuel
stove has an enclosed, non-removable
cover and national regulations are com-
plied with. This restriction does not
apply to gas cookers and gas hobs.

The closer the extractor hood is to

the hob, the greater the possibility that
rising steam will condense into drops
below the extractor hood.

Before reading 

this manual, please

unfold the illustrations at the back.

Old appliances still have some resi-

dual value. An environment-friendly
method of disposal will ensure that
valuable raw materials can be recovered
and used again.

Before you dispose of your old applian-
ce, make sure that it has been rendered
inoperable.

Your new appliance was protected

by suitable packaging while it was on its
way to you. All materials used for this
purpose are environment-friendly and
suitable for recycling. Please make a
contribution to protecting the environ-
ment by disposing of the packaging
appropriately.

Up-to-date information concerning opti-
ons for disposing of your old appliance
and the packaging from the new one
can be obtained from your retailer or
local government office.

The extractor hood can be used for

both exhaust (vented) and recirculation
(ventless) operation.

Always position the extractor hood

over the middle of the hob.

The minimum distance between the

hob and the lower edge of the extractor
hood is                          

650 mm,

Fig. 1.

Additional directions concerning gas
cookers:

Current installation specifications and

directives of the gas appliance manufac-
turers must be complied with.

Only one side of the extractor hood

should be next to a full-height cabinet
or a wall. Minimum distance: 50 mm.

5750.175 652-en  16.11.2006  9:35 Uhr  Seite 2

Summary of Contents for D 26 Series

Page 1: ...Installation instructions for the built in cooker hood D 26 NEFF GB Ltd ...

Page 2: ...fore reading this manual please unfold the illustrations at the back Old appliances still have some resi dual value An environment friendly method of disposal will ensure that valuable raw materials can be recovered and used again Before you dispose of your old applian ce make sure that it has been rendered inoperable Your new appliance was protected by suitable packaging while it was on its way t...

Page 3: ...operation of coo king appliances such as hobs and gas cookers Exhaust air routing must always comply with local authority regulations If the extraction hood is used in recircu lating operation with activated carbon filter unrestricted operation is possible With exhaust mode a backwash valve should be installed unless it is already incorporated in the exhaust pipe or wall box Fig 3 If a backwash va...

Page 4: ...tor comes as standard equip ped with a protective grid in the air connec tor If this is has been removed in the case of exhaust air operation the air connector must be supplemented by a reducer piece with protective grid see section on special accessories in the instruction manual Electrical connection WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT Fitting a Different Plug The wires in the mains...

Page 5: ...tightened Fig 12 7 Connect pipes 8 Connect electricity Mounting the door Door thickness min 16 mm Door height 380 to 700 mm Door weight max 7 kg In order to match the wall cabinets on either side the door can project at the top and bottom Fig 13 1 Remove the two door carriers to the right and left by pulling both the red plastic catches inwards and removing the door carrier out towards you Fig 14 ...

Page 6: ...40 210 120 230 140 300 140 260 140 290 360 Ventilation capacity in m3 h according to DIN 44971 and freeblowing Technical data Mounting wall covering rail The gap between the hood and the rear wall can be dressed with the enclosed covering rail Fig 18 Screw fasten the covering rail to the underside of the extractor hood Fig 18 Refit the grease filter see instruction manual If the unit door has to b...

Page 7: ...5750 175652 Printed in Germany 1106 Hi NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399 ...