background image

Page 13 of 13

Specifications

Power input

Input voltage  

12 VDC

Power Usage 

1 W

Connector 

2 pin screw block

 

Power adaptor (included)

Input voltage  

100 VAC – 240 VAC

Line frequency 

50 Hz – 60 Hz

Max power usage 

Max 8 W

 

RS-232 / IR port 

Ports 

1 x bidirectional

 

2 x uni-directional

Baud rate 

1200 – 115200 bit/sec

Data bits 

7, 8

Parity 

Even, Odd, None

Stop bits 

1, 2

IR frequency 

400 Hz to 500 KHz

Connector 

3 pin screw block

 

IR learn 

IR Learn frequency 

1 KHz to 150 KHz

 

Product number 

310-0102 

SieRRa II EU, white

310-0202 

SieRRa II DK, white

310-0402 

SieRRa II US, white

 

Compliancy 

IEC/EN 61000-6-1
IEC/EN 61000-6-2
FCC 

Part 15, Class A 

CE 

Input / Output 

Ports 

3 x I/O

Input trigger low 

< 1VDC

Input trigger high 

> 4VDC

 

Output type 

Open drain

Isolated output 

No

Max voltage load 

24 VDC

Max current 

0.5 A

Connector  

4 pin screw block 

 

Network (LAN)

Speed 

10 / 100 Mbit

Duplex modes 

Half or Full

DHCP 

Default off

Default IP 

192.168.254.252

Default gateway 

192.168.1.1

Default subnet mask 

255.255.255.0

 

Power over Ethernet 

Compliance 

802.3af / 802.3at

802.3af mode 

A + B

PD Class 

1

General 

Width, EU 

55 mm

Height, EU 

55 mm

Depth, EU 

17 mm

Width, DK 

45 mm

Height, DK 

72 mm

Depth, DK 

17 mm 

Width, US 

45 mm

Height, US 

105 mm

Depth, US 

24 mm

Weight, EU/DK 

90 g

Shipping weight 

0,3 kg

Shipping dimension:  

EU, DK

(W/D/H) 

155x85x55 mm 

Shipping dimension:  

US

(W/D/H) 

150x170x55 mm

Storage temperature 

-20 °C to 50 °C

Storage moisture 

Non-condensing

Operation temperature 

0 °C to 30 °C

Operation moisture 

Non-condensing

Summary of Contents for SieRRa II 310-0102

Page 1: ...Neets Control SieRRa II SieRRa II EU P N 310 0102 SieRRa II DK P N 310 0202 SieRRa II US P N 310 0402 User Manual...

Page 2: ...ts dk or you may use our contact form at www neets dk Revision list This document no 310 0102 001 009 001 has the following revision changes Author Date Description Pages Rev MH 10 06 2015 First relea...

Page 3: ...components inside These openings must never be blocked by other objects Do not use this equipment near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moistu...

Page 4: ...ontents 4 Description 5 Quick guide to the SieRRa II 6 Installation 7 Connections and Controls 9 Power input port 9 I O ports 9 RS 232 IR port 9 NEB port 10 LAN port 11 Buttons 11 Configuration throug...

Page 5: ...y to install SieRRa II can control devices through IR RS232 or even LAN SieRRa II is available in polar white and anthracite The drawings in the manual of Neets Control SieRRa II is based on the DK US...

Page 6: ...x RS 232 or IR ports Unidirectional 4 1 x RJ 45 Network LAN connector with PoE functionality 5 3 x Digital Input Output 6 1 x NEB bus port 1 A V MUTE OFF DVD PC 1 BLUERAY PC 2 SCREEN 3 2 1 2 Neets Con...

Page 7: ...ystem in the back box or on the bracket DK version Insert a flathead screwdriver gently and pry out the front cover Remove the front cover and the paper label behind it Insert a flathead screwdriver i...

Page 8: ...sert a flathead screwdriver gently and pry out the front cover Remove the front cover and the paper label behind it Insert the control system in a frame matching the back box used Insert screws matchi...

Page 9: ...nection to a PIR movement sensor keyboard lock relays or for other compatible uses The ports are not potential free you may need external relays to prevent ground loops depending on your application W...

Page 10: ...er Connect your NEB devices to this port with a cable not exceeding 20 cm of length Connec tions are PWR to PWR NCL to NCL NDA to NDA and GND to GND If additional cable length is needed in your applic...

Page 11: ...r LED light to indicate current status of the AV system Button function and LED indication are set up using the Neets Project Designer software Configuration through USB port The USB port is used excl...

Page 12: ...In this case try uploading an empty project and see if this works 1 Flashing 2 Flashing 3 Off 4 Off Unexpected Error o Turn off the power to the control system for 20 sec before turning the power on a...

Page 13: ...Output Ports 3 x I O Input trigger low 1VDC Input trigger high 4VDC Output type Open drain Isolated output No Max voltage load 24 VDC Max current 0 5 A Connector 4 pin screw block Network LAN Speed 1...