Installation

The Neets Control – TanGo is designed to be easily installed in any convenient location. The unit can be 

placed on a desk free standing. Simply unpack the unit, mount the adhesive feet and it is ready to go. 

 

Alternatively, the unit can be mounted under a table or on a ceiling with the included self-tapping 

screws. Unpack the unit, place the unit on the surface where it is to be mounted, and screw the 

two screws through the holes in the top as shown below: 

The unit also can be mounted in a 19 inch standard rack using the Neets Rack Shelf (Part number: 

306-0017). See separate manual for installation instructions.

310-0305-002-004 REV1  (Silkscreen Top plate)

designed in Denmark

Neets Control - TanGo

on

control

config

2

1

tx

rx

4

3

5

in / out

1 2 3 4

in

out

5 6 7 8

relay

on

ir

1

2

3

4

poe

Summary of Contents for Control TanGo

Page 1: ...Neets Control TanGo Installation Manual...

Page 2: ...ur local distributor or Neets A S Langballe 4 8700 Horsens Denmark by E Mail Support Neets dk or you may use our contact form at www neets dk Revision list This document has the following revision cha...

Page 3: ...mponents inside These openings must never be blocked by other objects Do not use this equipment near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture...

Page 4: ...ty Instructions 3 Contents 4 Description 5 Function Description 5 Specifications 5 Specifications 6 Installation 7 Connection and Controls 8 Front 8 Back 10 How to connect 13 PoE power supply to TanGo...

Page 5: ...eets extension devices and connection to Central Control and Project Designer as well as access to graphical user interface Power over Ethernet PoE PoE IN for power of the TanGo and PoE OUT for power...

Page 6: ...t IP 192 168 254 252 Default gateway 192 168 1 1 Default subnet mask 255 255 255 0 PoE input Compliance 802 3af 802 3at 802 3af PD mode A B PD Class 0 802 3af 4 802 3at PoE output Compliance 802 3at M...

Page 7: ...the included self tapping screws Unpack the unit place the unit on the surface where it is to be mounted and screw the two screws through the holes in the top as shown below The unit also can be moun...

Page 8: ...O status LED displays current status of the I Os When an IO is configured as input the yellow LED marked in will illuminate when the input is high and turn off when the input is low The green LED mark...

Page 9: ...e Neets Device Editor software through the USB port This enables learning of IR codes from your existing IR remote for easy configuration on site or at your desk Power and Error Indication The on LED...

Page 10: ...ors The onboard RS 232 ports T1 R1 T2 R2 T3 R3 can be used for two way communication with external RS 232 compatible devices The ports T4 and T5 can be used for one way communication with external RS...

Page 11: ...NEB extender Therefore you need an extender for all your NEB units as well 310 0305 0 Relays 1 G PWR NCL NDA NEB I O ports G 1 2 4 3 G 5 6 8 7 RS 232 IR G T2 R2 G T4 T5 G T1 R1 G T3 R3 Relays 1 G PWR...

Page 12: ...terminals are not connected when the relay is off LAN Connectors with PoE functionality The LAN connector is used to connect the TanGo to the local area network The TanGo has Power over Ethernet func...

Page 13: ...3 G 5 6 8 7 RS 232 IR G T2 R2 G T4 T5 G T1 R1 G T3 R3 PoE IN PoE OUT Relays 1 2 3 4 G PWR NCL NDA NEB LAN I O ports G 1 2 4 3 G 5 6 8 7 RS 232 IR G T2 R2 G T4 T5 G T1 R1 G T3 R3 PoE IN PoE OUT 310 03...

Page 14: ...he power loss in the cables and shut down the output if this loss is too high In practice this means that for example when using 100 meters of Cat5e cable between the PoE switch and the TanGo plus yet...

Page 15: ...nput Missing SD card or error on SD card Make sure that there is a SD card inserted in the control system After doing the above turn off the power to the control system for 20 seconds before turning t...