21
EN Operating Instructions
8.2 Unit menu
Symbol
Description
Vibration sensitivity
The threshold of the vibration sensitivity can be switched
between OFF, COARSE and FINE. By default, the
COARSE threshold is set.
The function is active 60 seconds after the laser has
levelled itself horizontally. Depending on the setting, a
movement of the laser then triggers a warning.
OFF
The laser read-
justs automatical-
ly during a vibra-
tion. A vibration
does not trigger a
warning.
COARSE
The Laser switch-
es off in case of
strong vibrations.
The warning then
appears on the
display:
FINE
The laser switch-
es off with even
if the vibration is
light. The warn-
ing then appears
on the display:
Referencing
In case of particularly high accuracy requirements, ad-
ditional referencing can be started manually. Additional
referencing can also improve the accuracy in case of large
temperature changes (e.g. after acclimatising the unit).
The unit checks the precise 0% reference.
Info
The software version, the serial number, the service date,
remaining time until the next service and the remaining
battery capacity can be called up via the info menu.
Service
T
his menu is only accessible to
authorised service technicians.
Summary of Contents for TUBUS 2