L-PAK 150/250 Advanced

9

EN

FlexPAK

Idling

TimeToStandby

12:00m

ESC

OK

Time to Standby: The amount of time until the 

unit goes into Standby mode. The default setting 

is 12 minutes. See Section 

6.2.5. SSR_Time.

5.1.5 

Filter Cleaning

The unit is cleaning its filter.

Filter

Cleaning

Clean 00:00

Wait 00:00

ESC

OK

Clean: How long the filter cleaning valve is open.

Charge: Vacuum charge time.

5.2 

Warning messages

If a warning is activated, there is a problem that needs to be corrected, but the 

unit continues to work. 

5.2.1 

Time for service

The time interval set in the ‘Service Interval Setting’ menu has expired. If this 

alarm is activated, the light in the Standby/Running button is lit one second 

and then again in 7 seconds. This 1/7 on/off sequence continues until the 

warning is reset.
Reset the alarm by first putting the unit into Off mode. Restart the unit. In 

Standby mode, press the manual filter cleaning button for 10 seconds. 

Time for

Service

Time when fault

occured

Reset OK ==>

ESC

OK

 

5.2.2 

Fan Hi Temp 

The fan is overheated. The temperature is greater than 125°C, and the filter 

cleaning valve is open to cool the fan. When the Fan-temperature is below 

90°C, the filter cleaning valve closes and vacuum is reestablished again.

Fan Hi Temp

Fan Cooling

Time when

fault occured

Reset OK ==>

ESC

OK

 

5.3 

Alarms

If an alarm is activated, the unit goes into Off mode until the problem is 

corrected. The alarm needs to be reset by pressing ‘OK’.

5.3.1 

Alarm Fan Hi Temp

The fan temperature has been too high for more than 8 minutes. The filter 

cleaning valve has been open to cool the fan more than 8 minutes, and the 

Summary of Contents for L-PAK Series

Page 1: ...L PAK Series L PAK 150 250 Advanced 50Hz 60Hz 2130144 00 2016 12 09 Original PLC manual EN PLC MANUAL PLC Manual...

Page 2: ......

Page 3: ...L PAK 150 250 Advanced 3 Figures 4 English 5...

Page 4: ...OK DIR_Time T 10 00s Ta 00 00 FlexPAK Idling TimeToStandby 00 12m ESC OK 4 PS 2 FlexPAK Off Standby TimeToService 2000Hour ESC OK 1 Nederman FlexPAK Off TimeToService 2000Hour ESC OK ESC OK SSR_Time T...

Page 5: ...p 9 5 3 Alarms 9 5 3 1 Alarm Fan Hi Temp 9 5 3 2 Motor Protector Activated 10 5 3 3 Low Pressure CAS 10 6 PLC settings 10 6 1 Find a parameter and set its value 10 6 2 Parameter settings 11 6 2 1 Adju...

Page 6: ...y the carrier and the local Nederman representative immediately 2 Safety This document contains important information that is presented as either a warning caution or note See the following examples W...

Page 7: ...5 SSR_Time The unit stays in Running mode as long as there is an active pilot signal However the unit can still be put into Off mode by pressing the Standby Running button Note that if only one workst...

Page 8: ...ed and the unit is waiting for a pilot signal to go into Running mode Standby Waiting for pilot signal 2012 07 02 ESC OK 5 1 3 Running Running mode The unit in Running mode The pump motor is on and th...

Page 9: ...again in 7 seconds This 1 7 on off sequence continues until the warning is reset Reset the alarm by first putting the unit into Off mode Restart the unit In Standby mode press the manual filter cleani...

Page 10: ...problem and press OK to reset the warning Motor Protector Activated Time when fault occured Reset OK ESC OK 5 3 3 Low Pressure CAS The compressed air level is low When the accurate pressure is establi...

Page 11: ...can be changed 8 Use or to set the value 9 Press OK to confirm 10 Press ESC to go to the main menu 11 Press ESC to go to the date and time screen 12 Press to exit 6 2 Parameter settings The following...

Page 12: ...01 7 The cursor shows the day of the week which flashes since it is the first value that is selected 8 Change the weekday with or 9 Move the cursor to the next position with or 10 Make any other nece...

Page 13: ...the unit is switched off even when a valve remains open for example over night NOTE If the weekly timer has been activated the amount of time the unit can be used during the day before it automaticall...

Page 14: ...nu for setting the service interval The default value is 2000 hours H Meter 1 MI 2000h ESC OK MI 2000h The amount of time between service intervals 6 2 4 DIR_Time Menu for setting the DIR timer The DI...

Page 15: ...ng cycle is 15 seconds 3 TH TL 3 5 15 where TH 02 00s and TL 03 00s ClenCyl TH 02 00s TL 03 00s Ta 00 00 ESC OK TH 02 00s The default time for the FCV to be open TL 03 00s The default time for the FCV...

Page 16: ...is used filter cleaning is not activated until this input is deactivated If this input is activated during a filter cleaning sequence the filter sequence stops immediately and the unit establishes a...

Page 17: ...there is no need to go all the way to L PAK Advanced to restart it 6 9 Standby Ready indicator The H1 lamp Output DO1 acts as a Standby unit ready indicator When the unit is in Standby mode or the fa...