GB
GB
1. Press
OK.
2. Step forward with
4
to the character to be changed.
3. Select an appropriate value with
5
or
6
, time in
seconds.
4. Confirm the change with
OK.
Setting the time for the automatic cleaning func-
tion.
1. Press
OK.
2. This it the time that the filter cleaning plate is open.
Step forward with
4
to the character to be changed.
3. Select an appropriate value
5
or
6
.
4. Step forward with
4
to Tl which is the time between
filter cleaning. Select character to be changed. Time
is shown in minutes.
5. Select an appropriate character with
5
or
6
.
6. Confirm the change with
OK.
Setting the post-running-time
1. Press
OK.
2. This is the time the unit runs before it stop. Select
required character with
4
.
3. Select an appropriate value with
5
or
6
. Time is
shown in minutes.
4. Confirm the change with
OK.
Start display.
Unit in waiting position.
The unit in operation. The unit´s current vacuum is
shown in the display, e.g. -20kPa
Warning messages
Time for service, date shows when the message was
activated.
Connected compressed air below 3 bar. TH 16:00 is the
weekday and the time the fault was activated.
Fan temperatur to high.
The unit goes into a cooling mode with a lower vacuum
level.
If a sensor for level indicating is installed this message
is shown when the collector bin is full. The time the unit
should run between varning and alarm can be adjusted.
In alarm mode the unit stops.
7
RUNNING
-20 kPa
TmeToService
2000Hour
ESC
OK
PLC-15
Time for
Service
2004-10-25
ESC
OK
PLC-19
CAS <3bar
TH 16:00
Reset OK
ESC
OK
PLC-20
FltClean
Th = 01:00s
TI = 60:00m
Ta = 00:00
ESC
OK
PLC-12
SSR_Time
T = 10:00m
Ta = 00:00
ESC
OK
PLC-13
Nederman
FlexPAK
TmeToService
2000Hour
ESC
OK
PLC-1
NEDERMAN
Standby
TmeToService
2000Hour
ESC
OK
PLC-14
Fan Hi Temp
TH 01:00
ESC
OK
PLC-25
Dustbin
Full
TH 01:00
Reset OK
ESC
OK