5.13 Test Pattern
The test pattern function allows you to check that data is being transferred correctly
from the camera. The test pattern is generated in the FPGA.
The Test Pattern can be output by using the camera control registers.
Setting should be done through the TestImageSelector register (see 5 .1)
Pixels 1 through Pixel 2048 output values incrementing from 0.
5.13.1 Test Pattern Setting Example (Pattern 1)
Switches between Test Pattern and image data output
register name: TestImageSelector
setting value : 0(Off),
1(GreyHorizontalRamp),
2(GreyHorizontalRampMovingEachLine)
(Example)GreyHorizontalRamp
Figure 5-13-1 FrameTriggerMaskTimeF register
(
the GigEGrab picture
)