![Nectre Fireplaces WONDERFIRE Installation & Operating Manual Download Page 23](http://html1.mh-extra.com/html/nectre-fireplaces/wonderfire/wonderfire_installation-and-operating-manual_3814058023.webp)
23
SEQUENCE OF OPERATION
REGULATOR ADJUSTMENT & CONVERSION DETAILS
1. Remote control calls for heat and sends signal.
2. Signal received by receiver. Beep sound should be audible from appliance.
3. Receiver performs internal safety check.
4. Gas control actuates pilot gas and starts ignition of pilot.
5. Ignition sparks for pilot.
6. Upon pilot lighting flame sensing occurs and sparking stops.
7. Main valve opens allowing main burner to cross ignite from pilot.
8. Heater will operate as per remote settings.
9. Remote control sends signal to stop heat.
10. Signal received by receiver. Audible beep from appliance should be heard.
11. Gas control turns off main burner and pilot.
Regulator where fitted is not adjustable – refer valve adjustments.
Appliance is Natural gas only – conversion not permitted.