20
SERVICING DETAILS
(continued)
GAS CONTROL – Proflame 885
The SIT electronic gas control and valve is situated under the burner tray. To access; remove the
coals and disconnect the gas supply. Remove the burner and place upside down on a flat surface
covered with old newspaper.
All wiring diagram is connected by non interchangeable plugs and sockets.
The burner pressure test point is on the front centre of the valve. It is the lower test point, the upper
being the inlet gas pressure.
Remove test point plug and connect manometer. Switch the gas and appliance on. Take pressure
reading once unit is running and it should be within tolerance. Turn unit and gas off, disconnect
manometer and tighten test point plug.
BURNER PRESSURE ADJUSTMENT
Burner test point pressures must be checked whilst appliance is running. Pressures are not
adjustable. Pilot pressure is adjustable.