10
© by NECTA VENDING SOLUTIONS SpA
0404 211 - 02
CONNECTING THE MACHINE
TO THE POWER SUPPLY
The machine is designed to operate under a single-phase
230 V~ voltage and is protected by T6.3 A fuses.
Before making the connection, ensure that the rating
corresponds to that of the power grid, and more specifi-
cally:
- the supply voltage rating must be within the range
recommended for the connection points;
- the main switch should be capable of withstanding the
peak load required, and at the same time ensure
proper omnipolar disconnection from the power grid
with an opening gap of the contacts of at least 3 mm.
The switch, the power outlet and the plug must be
located in an easily accessible position.
The electrical safety of the machine is ensured only when
it is correctly earthed according to the safety standards in
force.
This fundamental safety requirement must be duly
verified, and if in doubt the system must be carefully
tested by qualified technicians.
The power supply cable is of the type with a fixed plug. Any
replacement of the power cable (see figure) should be
made by qualified and suitably trained personnel only
using cables type HO5 RN - F or HO5 V V-F or H07 RN-
F with a 3x1-1.5 mm
2
section.
CONTROLS AND INFORMATION
The user controls and information are located on the
outside of the sliding compartment (see Fig. 13).
The credit and all function messages are indicated on the
display.
The keypad contains a series of numbered keys. To select
a product, key in the double digit number corresponding to
the desired product.
Key is used to cancel a selection already made.
Keys and are not available to the user; they are used
only for programming.
Fig. 13
1 - Lift cover
2 - Cable clamp
3 - Power supply cable
Do not use adapters, multiple sockets and/or exten-
sions.
THE MANUFACTURER DECLINES ALL RESPONSI-
BILITY FOR ANY DAMAGE CAUSED BY NON-COM-
PLIANCE WITH THE ABOVE MENTIONED PRECAU-
TIONS.
Fig. 14
1 - Door opening hand grip
2 - Advertising spaces
3 - Prearrangement for bill accepter
4 - Prearrangement for key type payment systems
5 - Display
6 - Coin slot/return.
7 - Selection keypad
8 - Lock
9 - Glass front
10 - Coin return flap
11 - Product flap
12 - Ventilation grille
INTERNAL COMPONENTS
The evaporator assembly mounted on the cabinet shelf
comprises two fans, the evaporator, the air duct and a
water retaining tray placed under the evaporator.
The CPU board (central processing unit) fitted inside the
payment system compartment controls the different func-
tions of the vending machine.