4
© by NECTA VENDING SOLUTIONS SpA
0404 211-02
TECHNICAL SPECIFICATIONS
Power supply voltage
230
V
~
Power supply frequency
50
Hz
Absorbed power
510
W
Max. operating conditions:
Ambient temperature
32
°C
Relative humidity
65%
Refrigeration system:
Compressor’s refrigeration output
320
W
Fan-forced evaporator
Programmable defrosting cycle
DIMENSIONS
Height
1830
mm
Width
880
mm
Depth
890
mm
Overall depth with door open at 90°
1494
mm
Weight (approx.)
290
Kg
SALES PRICES
A different programmable price can be set for each single
selection.
COIN BOX
Cover and lock are available as an optional feature.
CONTROLS AND SAFETY DEVICES
- Payment system compartment switch
- Timeout for power supply to dispensing motors
- Compressor overheating protection
- Line fuses
- Fuses on transformer primary and secondary windings
ACCESSORIES
A wide range of accessories can be installed on the
machine, to vary its performance.
The installation kits are supplied with their own installation
and test instructions, which must be strictly observed to
ensure the machine safety.
Installation and the following testing operations must
be carried out exclusively by personnel who have a
specific knowledge of the machine functions from a
point of view of electrical safety and health regula-
tions.
POWER CONSUMPTION
The machine power consumption depends on many fac-
tors, such as temperature and ventilation of the room
where it is installed, temperature of loaded products,
internal temperature of the refrigerated box.
Under average conditions, and namely:
- Ambient temperature:
20°
C
- Refrigerated box temperature:
5°
C
- temperature of loaded products
(machine completely empty)
20°
C
the following power consumption levels resulted:
- power consumption in 24 hour of stand-by 6,485 Wh
The above power consumption calculated from average
data should only be taken as an indication.
Fig. 2
PAYMENT SYSTEM
The machine can be supplied with the electrical setup for
the installation of systems with the following protocols:
Executive, MDB, BDV and MDB
24 V DC validators.
Beside the coin mechanism housing, suitable space is
provided for the installation (optional) of the most widely
used payment systems.
Summary of Contents for Sfera