Solving Problems 7-3
START-UP PROBLEMS
The system displays an invalid configuration error message at power on
when there are the following conditions:
the current configuration information doesn't match configuration infor-
mation stored in Auto Setup, such as when an internal option is added.
the system loses configuration information.
If either condition is true, the system displays an “invalid configuration in-
formation” message.
To continue start-up procedures, press
F2
and run the Setup utility to set
current system parameters.
If an error message appears before the operating system starts, look up the
error message in the following table. Follow the instructions. If you see other
error messages, the hardware might need repair.
NOTE
When the NEC Versa detects an error related to display de-
vices, it cannot display on either the LCD or a CRT. The system
warns you by beeping.
POST Error Messages
The NEC Versa 6200MX has a built-in checking program that automati-
cally tests its components when you turn the system power on. This diag-
nostic test is called the Power-On Self-Test (POST). If the system finds a
problem during the POST, the system displays an error message or emits a
series of beep signals. If this happens, follow the instructions in the POST
Error Messages table or the Beep Code table, as appropriate.