Program 41 : ACD Setup
41-16 : ACD Threshold Overflow
Level:
SA
Description
Use
Program 41-16 : ACD Threshold Overflow
to define the value of the ACD threshold call
overflow and the mode for each ACD group.
Input Data
ACD Group No.
1 ~ 8
Item
No.
Item
Input Data
Description
Default
01
Number of Calls in
Queue
0 ~ 128
0 = No Limitation
Define the maximum number of calls al-
lowed in the ACD queue before overflow
occurs.
0
02
Operation Mode for
ACD Queue
0 = The last waiting call
is transferred
1 = The longest waiting
call is transferred
2 = Send Busy Tone
Define how the system should handle calls
when the number of calls in queue ex-
ceeds the threshold.
0
Conditions
None
Feature Cross Reference
• Automatic Call Distribution (ACD)
ISSUE 1.0
SL2100
ACD Installation Manual
4-59