CHAPTER 5 OPERATION TEST
– 425 –
NWA-008853-001 Rev.3.0
97ch5001.fm
Alarm Indications on 24CCT
LED
LED INDICATION
FAULT
NORMAL
FAULT
CAUSE
ACTION
RUN
Flash
(120 IPM)
On or Off
Abnormal operation
of CCT card
Confirm the programming data:
CM05 Y=0/Y=1, CM07 Y=01.
Check to see if the SENSE switch
is set as per the AP number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch
(Down
→
Up
→
Down)
If the fault can not be cleared,
replace the card.
LC
On
Off
CCH link connec-
tion failure
Check the local office line or pub-
lic network line.
CRC
Off
On
Bit Error Rate
exceeds the prede-
termined value
Check the receive line and exter-
nal equipment.
Replace the remote CCT card.
PCM
Off
On
No PCM signals
arrive from the dis-
tant office
Check to see if the line is correctly
connected to the CCT card.
Plug and unplug the CCT card.
Repeat this two or three times.
FRM
Off
On
Frame Alignment
signals from the
distant office can-
not be received
Check the receive line and exter-
nal equipment.
Replace the remote CCT card.
Continued on next page
1
2
3
4
1
1
2
1
2
1
2
LOOPBACK TEST
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008853 001 ISSUE 3 0 CCIS System Manual...
Page 14: ...vi NWA 008853 001 Rev 3 0 97toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 18: ...4 NWA 008853 001 Rev 3 0 97ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 364: ...350 NWA 008853 001 Rev 3 0 97ch3005 fm THIS PAGE LEFT BLANK INTENTIONALLY JANUARY 31 2006...