CHAPTER 3 SYSTEM DATA PROGRAMMING
– 317 –
NWA-008853-001 Rev.3.0
97ch3005.fm
TOLL RESTRICTION-3/6 DIGITS-CCIS
General Description
This feature allows the system to be programmed to restrict outgoing calls, through CCIS, according to
specific Areas and/or Office codes. This restriction is determined on the basis of a three-digit Area Code
or six-digit Area and Office Code numbering plan.
Programming
DESCRIPTION
DATA
Provide the system with the Toll Restriction
feature for an outgoing call by Speed Calling-
System (System Speed Dialing)/Speed Call-
ing-Station (Station Speed Dialing), if desired.
(1)
(2)
035: Speed Calling-Station
(Station Speed Dialing)
0 : Not provided
1 : To provide
(1)
(2)
044: Speed Calling-System
(System Speed Dialing)
0 : Not provided
1 : To provide
Provide the system with Toll Diversion or Toll
Denial.
(1)
(2)
119
0 : Toll Diversion (Routed to “ICPT” key
on ATTCON)
1 : Toll Denial (Routed to Reorder Tone)
Assign a Trunk Restriction Class to each sta-
tion.
•
(1)
(2)
Y=01
X-XXXXXXXX: Station No.
X Z: Trunk Restriction Class
X: 1-8: In Day Mode
Z: 1-8: In Night Mode
1: Unrestricted (RCA)
2: Non-Restricted 1 (RCB)
3: Non-Restricted 2 (RCC)
4: Semi-Restricted 1 (RCD)
5: Semi-Restricted 2 (RCE)
6: Restricted 1 (RCF)
7: Restricted 2 (RCG)
8: Fully-Restricted (RCH)
START
CM08
CM12
A
TOLL RESTRICTION-3/6 DIGITS-CCIS
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008853 001 ISSUE 3 0 CCIS System Manual...
Page 14: ...vi NWA 008853 001 Rev 3 0 97toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 18: ...4 NWA 008853 001 Rev 3 0 97ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 364: ...350 NWA 008853 001 Rev 3 0 97ch3005 fm THIS PAGE LEFT BLANK INTENTIONALLY JANUARY 31 2006...